Uji Eksperimental Fenomena Water Hammer dengan Variasi Ketinggian Surge Tower
نویسندگان
چکیده
In this study an analysis of the water hammer process was carried out in a piping installation with two pumps different specifications arranged single arrangement. The solution given as form protection is variations height surge tower installations. aim research to identify phenomenon installations pump discharges and effect damper against pressure fluctuations that occur. test by closing valve suddenly varying determine value occurs due effect. From experimental results, it can be seen 1 meter best dampen back at discharge 2.4 m3/h. theoretical shows addition reduce drop 2.6 kg/cm2 2.2 from 4.6 1.8 2. use 2.78 hours s 1.4
منابع مشابه
Experimental and Numerical Simulation of Water Hammer in Water Conveyance Pipeline and Effect of Surge Tower Pipe in Controlling this Phenomenon
Water hammer is one of the unsteady flows in urban water distribution networks, which has been of great importance due to the damage caused to the pipeline and has always been of interest to researchers. In this study, the phenomenon of water hammer due to the sudden closure of the valve in the downstream end has been investigated in a laboratory and using a numerical model. In the laboratory s...
متن کاملSurge Tank Design Considerations for Controlling Water Hammer Effects at Hydro-electric Power Plants
A theoretical analysis based on some design considerations for surge tanks is carried out. The effects of different parameters such as the friction losses coefficient and the surge tank cross-sectional area on the water surface oscillations tank and the total discharge are investigated. System of non-linear ordinary differential equations are numerically solved and manipulated. Results show tha...
متن کاملWater Hammer with Column Separation:
Column separation refers to the breaking of liquid columns in fully filled pipelines. This may occur in a water hammer event when the pressure drops to the vapor pressure at specific locations such as closed ends, high points or knees (changes in pipe slope). A vapor cavity, driven by the inertia of the parting liquid columns, will start to grow. The cavity acts as a vacuum, a low-pressure poin...
متن کاملMultiple Scales Analysis of Water Hammer Attenuation
A multiple scales analysis is used to construct a uniformly accurate approximation to water hammer pressure wave attenuation that is initiated by a sudden valve opening. The method of analysis is well suited to the study of a water hammer that possesses several time scales and is applied to a mild generalization of the classical equations. It should prove useful for finding attenuation curves w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Jurnal Teknik Mesin Sinergi
سال: 2023
ISSN: ['1693-1548', '2684-9372']
DOI: https://doi.org/10.31963/sinergi.v21i1.4226