Type 1a Endoleak Secondary to Graft Migration
نویسندگان
چکیده
منابع مشابه
Type III Endoleak of a Disconnected Stent-graft Limb
A 70-year-old man, who had undergone the placement of an endovascular aneurysm repair graft for an abdominal aortic aneurysm 7 years previously, presented to our facility with the separation of a left iliac stent-graft limb from the main-body stent-graft, resulting in a type III endoleak. An attempt was made to repair the disconnected stent-graft limb with endovascular intervention. An extensio...
متن کاملEndograft Sizing for Endovascular Aortic Repair and Incidence of Endoleak Type 1A
OBJECTIVE In endovascular aortic aneurysm repair (EVAR), proximal type 1A endoleaks can occur as a result of hostile neck anatomy or over- or undersizing of the endograft. As the current standard is based on the diameter or average of the short and long axes in a central lumen reconstruction image, it can falter in irregularly shaped aortic necks. An alternative method is circumference-based, t...
متن کاملLate Type 3b Endoleak Mimicking Type 2 Endoleak after Endovascular Aortic Aneurysm Repair
Endovascular abdominal aortic aneurysm (AAA) repair has been widely used for the treatment of AAA as a safe and efficient method, but endoleaks causing persistent expansion of aneurysm sac may cause aneurysmal rupture and death. Type 3 endoleak is rare but a predominant cause of late rupture. Type 3b endoleak can be misdiagnosed as type 2 endoleak, which is more frequent. Here we report two cas...
متن کاملDelayed Type IIIb endoleak secondary to graft fabric tear 7 years following implantation of a Medtronic Talent endovascular aortic device: A case report and review of the literature
OBJECTIVES To report a rare case of delayed Type IIIb endoleak secondary to fabric tear following implantation of a Medtronic Talent endovascular device. METHODS A 83-year old gentleman underwent elective endovascular aneurysm repair for infrarenal abdominal aortic aneurysm with a Medtronic bifurcated stent graft in 2008. RESULTS Seven years after the initial repair, imaging surveillance re...
متن کاملRescue Therapy of Inadvertent Coil Migration for Endovascular Treatment of Type II Endoleak
Coil migration during endovascular procedures is not an unusual complication, but there is no standard management strategy for bailout. Here, we describe a technique for removal of a migrated coil using a snare. During embolization of type II endoleak from the inferior mesenteric artery in a post-endovascular aneurysm repair patient, the coil migrated to the sigmoidal artery causing an occlusio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: European Journal of Vascular and Endovascular Surgery
سال: 2019
ISSN: 1078-5884
DOI: 10.1016/j.ejvs.2019.01.014