Two Winding Transformer Equivalent Model of Three Winding Transformers for MATPOWER

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A High Frequency Transformer Winding Model for FRA Applications

Frequency response analysis (FRA) is a method which is used to detect mechanical faults in transformers. The FRA response of a transformer is determined by its geometry and material properties, and it can be considered as the transformer’s fingerprint. If there are any mechanical changes in the transformer, for example if the windings are moved or distorted, its fingerprint will also be changed...

متن کامل

overvoltage caused by winding terminal arrangement of three phase transformer

usually both ends of a transformer winding are at the same side of the magnetic core. with this arrangement there are automaticaly the same number of the turns for each winding in both core windows next to the middle leg of a three phase three leg core type transformer. contrary to this arrangement it is possible to put the two ends of a winding at the different sides of the core. in this case ...

متن کامل

Characterization of Power Transformer Electromagnetic Forces Affected by Winding Faults

Electromagnetic forces in power transformer windings are produced by interaction between the leakage fluxes and current passing them. Since the leakage flux distribution along the windings height is in two axial and radial directions, so the electromagnetic forces have two components, radial and axial. There is a risk that a large electromagnetic force due to the short circuit or inrush current...

متن کامل

Identifying the Magnetic Part of the Equivalent Circuit of n -Winding Transformers

Representation of multiwinding transformers by equivalent circuits has been recently improved, and it is for the identification of components of these circuits. In this paper, the focus is on magnetic coupling with its related losses. A general method, based on external impedance measurements, is followed to determine inductances, coupling ratios, and resistances included in these equivalent ci...

متن کامل

High-Frequency Modeling and Simulation of a Single-Phase Three-Winding Transformer Including Taps in Regulating Winding

—Transformer terminal equivalents obtained via admittance measurements are suitable for simulating high-frequency transient interaction between the transformer and the network. This paper augments the terminal equivalent approach with a measurement-based voltage transfer function model which permits calculation of voltages at internal points in the regulating winding. The approach is demonstrat...