Two-tier model for nucleate pool boiling on microconfifured composite surfaces
نویسندگان
چکیده
منابع مشابه
Roughness Effects on Nucleate Pool Boiling of R-113 on Horizontal Circular Copper Surfaces
The present paper is an experimental investigation of roughness effects on nucleate pool boiling of refrigerant R113 on horizontal circular copper surfaces. The copper samples were treated by different sand paper grit sizes to achieve different surface roughness. The average surface roughness of the four samples was 0.901, 0.735, 0.65, and 0.09, respectively. The experiments were performed in t...
متن کاملHeat transfer in nucleate pool boiling of multicomponent mixtures
Steady state pool boiling heat transfer coefficients have been obtained experimentally for acetone–isopropanol–water and acetone–MEK (methyl ethyl ketone)–water ternary systems. The data show that, for a given heat flux, the heat transfer coefficients of mixtures are lower than those obtained for pure components constituting the mixture. The measured heat transfer coefficients were compared wit...
متن کاملNucleate boiling performance on nano/microstructures with different wetting surfaces
A study of nucleate boiling phenomena on nano/microstructures is a very basic and useful study with a view to the potential application of modified surfaces as heating surfaces in a number of fields. We present a detailed study of boiling experiments on fabricated nano/microstructured surfaces used as heating surfaces under atmospheric conditions, employing identical nanostructures with two dif...
متن کاملMomentum effects in steady nucleate pool boiling during microgravity.
Pool boiling experiments were conducted in microgravity on five space shuttle flights, using a flat plate heater consisting of a semitransparent thin gold film deposited on a quartz substrate that also acted as a resistance thermometer. The test fluid was R-113, and the vapor bubble behavior at the heater surface was photographed from beneath as well as from the side. Each flight consisted of a...
متن کاملDirect Numerical Simulation of Subcooled Nucleate Pool Boiling
With the long-term objective of Critical Heat Flux (CHF) prediction, a Direct Numerical Simulation (DNS) framework for simulation of subcooled and saturated nucleate pool boiling is developed. One case of saturated, and three cases of subcooled boiling at different subcooling levels are simulated. Grid refinement study is also reported. Both boiling and condensation phenomena can be computed si...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Communications in Heat and Mass Transfer
سال: 1992
ISSN: 0735-1933
DOI: 10.1016/0735-1933(92)90013-8