Two-Sample PLL With Harmonic Filtering Capability Applicable to Single-Phase Grid-Connected Converters

نویسندگان

چکیده

The two-sample phase locked loop (2S PLL) in single-phase digitally controlled grid-connected power converters provide synchronization with a minimal computational burden. However, the distortion of grid voltage deteriorates performance 2S quadrature signal generator. To solve this issue, article introduces harmonic filtering (HF) structure based on observers input for fundamental and selected harmonics. stability sensitivity PLL HF is analyzed. In comparison second-order generalized integrator (SOGI)-based HF, narrower bandpass, subsequent deterioration response time compensated by adapting filter gains dynamically. results obtained, both simulation experimentally, validate proposal compare its other widely adopted PLLs providing rejection capability. burden analyzed case proposals depends number use or not adaptive strategy steepest descent.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pll for Single Phase Grid Connected Inverters

In grid connected applications the synchronization of output signals of the converters to be connected with grid parameters frequency and phase is of great importance. Different methods based on Fourier transforms, zero-crossing detection, Kalman filters, phase-locked loops (PLL) and others are used for this synchronization. This paper presents a new PLL for synchronization of the output curren...

متن کامل

Design of a Digital Voltage Controller in Single-Phase Grid-Connected Renewable Converters

Power decoupling of pulsating grid side power from constant source side power is one of the paramount issues in single phase-phase grid-connected renewable systems. The principal aim of such systems is the decrease of the capacitance of the decoupled capacitor. However, this causes some problems such as an increase in the total harmonic distortion (THD) of injected current to the grid and bus v...

متن کامل

Reactive Power Sharing and Harmonic Voltage Modification in Single Phase Island Micro-Grid with Drop Control

Abstract: When several parallel inverters are in islands operating mode, the droop control scheme is usually used to control the inverters. The droop control method enables the inverters of a Micro-Grid to control the voltage and frequency of the network in a decentralized regulation behavior. The drop control method also enables the inverters to share the required active and reactive powers of...

متن کامل

Grid synchronization and symmetrical components extraction with PLL algorithm for grid connected power electronic converters – a review

In this paper, a review of Phase Locked Loop (PLL) algorithms and symmetrical component extraction methods intended for grid-connected power electronic converters are presented. Proposed classification is based on voltage representation in three coordinates: natural (abc), stationary (αβ) and rotating coordinates (dq). The three selected algorithms are described in details: Dual Second Order Ge...

متن کامل

Bifurcation Analysis of Three-Phase Grid-connected Converters

This thesis aims to identify and analyze the nonlinear behavior in the threephase voltage source converter, which is widely used as an interface converter in a distributed hybrid power system (DHPS). In this system, the converter does not work as a standalone converter but operates as a subsystem that connects to a non-ideal power grid and interacts indirectly with other subsystems via a point ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Journal of Emerging and Selected Topics in Power Electronics

سال: 2021

ISSN: ['2168-6777', '2168-6785']

DOI: https://doi.org/10.1109/jestpe.2020.2997847