Two-port network analyzer calibration using an unknown 'thru'
نویسندگان
چکیده
منابع مشابه
An Optimal Vector-Network-Analyzer Calibration Algorithm
We present an iterative algorithm for calibrating vector network analyzers based on orthogonal distance regression. The algorithm features a robust, yet efficient, search algorithm, an error analysis that includes both random and systematic errors, a full covariance matrix relating calibration and measurement errors, 95% coverage factors, and an easy-to-use user interface that supports a wide v...
متن کاملMeasurement of Multi-Port S-Parameters using Four-Port Network Analyzer
An efficient measurement methodology is proposed to construct the scattering parameters of a multi-port device using a four-port vector network analyzer (VNA) without the external un-terminated ports. By using the four-port VNA, the reflected waves from the un-terminated ports could be minimized. The proposed method significantly enhances the accuracy of the S-parameters with less number of mea...
متن کاملCalibration of a Metallic Access Network Analyzer
A calibration approach is proposed to compensate the systematic errors when the input reflection coefficient of a metallic access network cable is obtained using single port measurements from an access network analyzer. The analyzer is a versatile instrument and uses optimal cable matching and internal balancing to achieve maximum measurement resolution. The analyzer uses test-leads connected t...
متن کاملTwo-port microwave calibration at millikelvin temperatures.
In this work we introduce a system for 2-port microwave calibration at millikelvin temperatures operating at the coldest stage of a dilution refrigerator by use of an adapted thru-reflect-line algorithm. We show that this can be an effective tool for characterizing common 50 Ω microwave components with better than 0.1 dB accuracy at temperatures that are relevant to many current experiments in ...
متن کاملA Comparison of Acquired Port-wine Stain with Congenital Port-wine Stain Using an Image Analyzer.
BACKGROUND Recent reports have proposed that there were no differences between acquired port-wine stain (APWS) and congenital port-wine stain (CPWS) except the onset of disease. Pulsed dye laser (PDL) therapy is regarded as the treatment of choice in PWS. Although in some articles, APWS might have shown a better response to PDL than CPWS, this is still controversial. It has been assumed however...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Microwave and Guided Wave Letters
سال: 1992
ISSN: 1051-8207
DOI: 10.1109/75.173410