Two-point dixon fat–water separation: Improving reliability and accuracy in phase correction algorithms

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Linear phase-error correction for improved water and fat separation in dual-echo dixon techniques.

Large and spatially-linear phase errors along the frequency-encode direction may be induced by several common and hard-to-avoid system imperfections such as eddy currents. For data acquired in dual-echo Dixon techniques, the linear phase error can be more aggravated when compared to that acquired in a single echo and can pose challenges to a phase-correction algorithm necessary for successful D...

متن کامل

synthesis of platinum nanostructures in two phase system

چکیده پلاتین، فلزی نجیب، پایدار و گران قیمت با خاصیت کاتالیزوری زیاد است که کاربرد های صنعتی فراوانی دارد. کمپلکس های پلاتین(ii) به عنوان دارو های ضد سرطان شناخته شدند و در شیمی درمانی بیماران سرطانی کاربرد دارند. خاصیت کاتالیزوری و عملکرد گزینشی پلاتین مستقیماً به اندازه و- شکل ماده ی پلاتینی بستگی دارد. بعضی از نانو ذرات فلزی در سطح مشترک مایع- مایع سنتز شده اند، اما نانو ساختار های پلاتین ب...

Two-point water-fat imaging with partially-opposed-phase (POP) acquisition: an asymmetric Dixon method.

A novel two-point water-fat imaging method is introduced. In addition to the in-phase acquisition, water and fat magnetization vectors are sampled at partially-opposed-phase (POP) rather than exactly antiparallel as in the original Dixon method. This asymmetric sampling encodes more valuable phase information for identifying water and fat. From the magnitudes of the two complex images, a big an...

متن کامل

Regularized iterative reconstruction for undersampled BLADE and its applications in three-point Dixon water-fat separation.

In MRI, the suppression of fat signal is very important for many applications. Multipoint Dixon based water-fat separation methods are commonly used due to its robustness to B(0) homogeneity compared with other fat suppression methods, such as spectral fat saturation. The traditional Cartesian k-space trajectory based multipoint Dixon technique is sensitive to motion, such as pulsatile blood fl...

متن کامل

Self-Consistency: A Novel Approach to Characterizing the Accuracy and Reliability of Point Correspondence Algorithms

We propose a methodology that estimates the accuracy and reliability of the results of any multiple-image point correspondence algorithm, without the need for ground truth or camera calibration. The key concept behind our methodology is what we call the self-consistency of an algorithm across independent experimental trials (independent applications of the algorithm to subsets of images in a gi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Magnetic Resonance Imaging

سال: 2008

ISSN: 1053-1807,1522-2586

DOI: 10.1002/jmri.21310