Two-phase frictional pressure drop multipliers for SUVA R-134a flowing in a rectangular duct
نویسندگان
چکیده
منابع مشابه
pressure drop prediction of r-134a two phase flow inside evaporators
the pressure drop of refrigerant r-134a flow boiling inside a horizontal tube has been investigated experimentally. the test set-up which was used in this investigation is a well instrumented vapor compression refrigeration system. these instruments are thermocouples, flow meter, pressure gauges and the pressure drop measuring apparatus. this system consisted of three electrically heated evapor...
متن کاملNumerical Study of Single Phase/Two-Phase Models for Nanofluid Forced Convection and Pressure Drop in a Turbulence Pipe Flow
In this paper, the problem of turbulent forced convection flow of water- alumina nanofluid in a uniformly heated pipe has been thoroughly investigated. In numerical study, single and two-phase models have been used. In single-phase modeling of nanofluid, thermal and flow properties of nanofluid have been considered to be dependent on temperature and volume fraction. Effects of volume fraction a...
متن کاملUniversal approach to predicting two-phase frictional pressure drop for mini/micro-channel saturated flow boiling
This paper is a part of a recent series of studies by the authors to develop universal predictive tools for pressure drop and heat transfer coefficient for mini/micro-channel flows that are capable of tackling fluids with drastically different thermophysical properties and very broad ranges of all geometrical and flow parameters of practical interest. In this study, a new technique is proposed ...
متن کاملTwo Phase Flow Pressure Drop Calculation Using Homogeneous Equilibrium Model
Although two-phase flow is frequently encountered in various location of the process plants, there is no a general accepted and verified two-phase flow model that may be used to size lines for such conditions. An obvious example is condensate water return lines. The API method that used in this study is based on the homogeneous equilibrium flow assumption, that is, equal velocity and equal temp...
متن کاملTwo Phase Frictional Pressure Drop of Carbon Dioxide in Horizontal Micro Tubes
Two-phase frictional pressure drop data were obtained for condensation of carbon dioxide in single horizontal micro tube of inner diameter ranged from 0.6 mm up to 1.6 mm over mass flow rates from 2.5*10 to 17*10 kg/s and vapor qualities from 0.0 to 1.0. The inlet condensing pressure is changed from 33.5 to 45 bars. The saturation temperature ranged from -1.5 C up to 10 C. These data have then ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Multiphase Flow
سال: 2006
ISSN: 0301-9322
DOI: 10.1016/j.ijmultiphaseflow.2006.01.004