Two-phase flow measurements at high void fraction by a Venturi meter
نویسندگان
چکیده
منابع مشابه
ECT and LS-SVM Based Void Fraction Measurement of Oil-Gas Two-Phase Flow
A method based on Electrical Capacitance Tomography (ECT) and an improved Least Squares Support Vector Machine (LS-SVM) is proposed for void fraction measurement of oil-gas two-phase flow. In the modeling stage, to solve the two problems in LS-SVM, pruning skills are employed to make LS-SVM sparse and robust; then the Real-Coded Genetic Algorithm is introduced to solve the difficult problem...
متن کاملNumerical modeling of three-phase flow through a Venturi meter using the LSSVM algorithm
One of the challenging problems in the Oil & Gas industry is accurate and reliable multiphase flow rate measurement in a three-phase flow. Application of methods with minimized uncertainty is required in the industry. Previous developed correlations for two-phase flow are complex and not capable of three-phase flow. Hence phase behavior identification in different conditions to designing and mo...
متن کاملect and ls-svm based void fraction measurement of oil-gas two-phase flow
a method based on electrical capacitance tomography (ect) and an improved least squares support vector machine (ls-svm) is proposed for void fraction measurement of oil-gas two-phase flow. in the modeling stage, to solve the two problems in ls-svm, pruning skills are employed to make ls-svm sparse and robust; then the real-coded genetic algorithm is introduced to solve the difficult problem of ...
متن کاملA New Void Fraction Measurement Method for Gas-Liquid Two-Phase Flow in Small Channels
Based on a laser diode, a 12 × 6 photodiode array sensor, and machine learning techniques, a new void fraction measurement method for gas-liquid two-phase flow in small channels is proposed. To overcome the influence of flow pattern on the void fraction measurement, the flow pattern of the two-phase flow is firstly identified by Fisher Discriminant Analysis (FDA). Then, according to the identif...
متن کاملVoid fraction measurement in two-phase flow processes via symbolic dynamic filtering of ultrasonic signals
This communication introduces a non-intrusive method for void fraction measurement and identification of two-phase flow regimes, based on ultrasonic sensing. The underlying algorithm is built upon the recently reported theory of a statistical pattern recognition method called symbolic dynamic filtering (SDF). The results of experimental validation, generated on a laboratory test apparatus, show...