Two-Microelectrode Voltage Clamp of Xenopus Oocytes: Voltage Errors and Compensation for Local Current Flow
نویسندگان
چکیده
منابع مشابه
On-chip Non-invasive Voltage Clamp on Xenopus Oocytes
In order to improve the throughput of the traditional “Two Electrode Voltage Clamp” (TEVC) measurements on Xenopus oocytes, we present here a chip-based non-invasive technique for the measurement of ion channels activity. We focus especially on the integration of the electrical measurement site into a microfluidic structure, allowing rapid exchange of various small-volume solutions.
متن کاملThe Effectiveness of Dynamic Voltage Restorer with the Distribution Networks for Voltage Sag Compensation
This paper discusses the Dynamic voltage restorer (DVR) operation and control for Voltage sags compensation. DVR is a series connected power electronic based device that can quickly mitigate the voltage sags in the system and restore the load voltage to the pre-fault value. Voltage sag associated with faults in transmission and distribution systems, energizing of transformers, and starting of l...
متن کاملFast, triangular voltage clamp for recording and kinetic analysis of an ion transporter expressed in Xenopus oocytes.
We present a procedure for determination of 11 system parameters of an ion transporter expressed in Xenopus oocytes. The experiments consist of fast triangular voltage-clamp experiments in the presence and absence of external substrate. A four-state enzymatic cycle operating between an external and an internal section of electrodiffusion is used for analysis. The explicit example treats experim...
متن کاملControl of Inverter-Interfaced Distributed Generation Units for Voltage and Current Harmonics Compensation in Grid-Connected Microgrids
In this paper, a new approach is proposed for voltage and current harmonics compensation in grid-connected microgrids (MGs). If sensitive loads are connected to the point of common coupling (PCC), compensation is carried out in order to reduce PCC voltage harmonics. In absence of sensitive loads at PCC, current harmonics compensation scenario is selected in order to avoid excessive injection of...
متن کاملA New Control Strategy for Voltage Restoration and Voltage Unbalance Compensation in an Islanded Droop-Controlled Microgrid
Low voltage microgrids including sensitive loads often face unbalanced load conditions. Therefore, a compensation procedure should be carried out in order to balance and restore sensitive load’s voltage. In this paper, an effective voltage control strategy has been proposed for the autonomous operation of microgrids, under unbalanced load conditions. The proposed strategy balances single-phase...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Biophysical Journal
سال: 1999
ISSN: 0006-3495
DOI: 10.1016/s0006-3495(99)77039-6