Two-frame algorithm to design quadrature filters in phase shifting interferometry

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two-wavelength phase shifting interferometry.

This paper describes a technique that combines ideas of phase shifting interferometry (PSI) and two-wavelength interferometry (TWLI) to extend the phase measurement range of conventional single-wavelength PSI. To verify theoretical predictions, experiments have been performed using a solid-state linear detector array to measure 1-D surface heights. Problems associated with TWLPSI and the experi...

متن کامل

Two-step self-tuning phase-shifting interferometry.

A two-step self-tuning phase-shifting method is presented. The phase-step between the two interferograms is not known when the experiment is performed. Our demodulating method finds, in a robust way, this unknown phase-step. Once the phase-step is estimated we proceed to phase demodulate the interferograms. Moreover our method only requires the fringe patterns to have a constant unknown phase-s...

متن کامل

Analysis of the principal component algorithm in phase-shifting interferometry.

We recently presented a new asynchronous demodulation method for phase-sampling interferometry. The method is based in the principal component analysis (PCA) technique. In the former work, the PCA method was derived heuristically. In this work, we present an in-depth analysis of the PCA demodulation method.

متن کامل

Noise in phase shifting interferometry.

We present a theoretical analysis to estimate the amount of phase noise due to noisy interferograms in Phase Shifting Interferometry (PSI). We also analyze the fact that linear filtering transforms corrupting multiplicative noise in Electronic Speckle Pattern Interferometry (ESPI) into fringes corrupted by additive gaussian noise. This fact allow us to obtain a formula to estimate the standard ...

متن کامل

Phase shifter calibration in phase-shifting interferometry.

This paper describes some practical methods to calibrate the phase shifter in phase-shifting interferometry (PSI). The phase shifter used in the experiment is a piezoelectric transducer (PZT) that has a nonlinearity of <l%. Using the quantitative method described in this paper, the repeatability in the measurement of the phase-shifting angle is ̃9.046 rms, and the 3σ value is 0.139. A calibratio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Optics Express

سال: 2010

ISSN: 1094-4087

DOI: 10.1364/oe.18.024405