Two-dimensional beam profile monitor for the detection of alpha-emitting radioactive isotope beam

نویسندگان

چکیده

Ions with similar charge-to-mass ratios cannot be separated from existing beam profile monitors (BPMs) in nuclear facilities which low-energy radioactive ions are produced due to fusion reactions. In this study, we developed a BPM using microchannel plate and charge-coupled device differentiate the profiles of alpha-decaying isotopes other (reaction products) reaction. This was employed optimize francium ion (Fr+) at Cyclotron Radioisotope Center (CYRIC), Tohoku University, for electron permanent electric dipole moment (e-EDM) search experiments Fr atoms. We demonstrated performance by separating Fr+ reaction products during an oxygen (18O) gold (197Au) target. However, as mass Au is close that Fr, these elements filter challenge, dominant number Au+ renders invisible when typical BPM. Therefore, employing new BPM, could successfully observe beams distinctly measuring alpha decay isotopes. novel technique monitor alpha-emitting covers broad range lifetimes, example, approximately 1 s 10 min, can implemented alpha-emitter utilized medical applications.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Beam Intensity Profile Monitor

This paper describes an intercepting beam intenSity profile and position monitor which was developed at SLAC. It has excellent spatial resolution as well as signal efficiency. The instrument utilizes the electromagnetic cascade shower emission effect. Net charge leakage signals comparable in magnitude to the intercepted beam current are easily obtainable. The latest model of the instrument is d...

متن کامل

Scanning Electron Beam Profile Monitor

A scanning beam profile monitor is described that was developed for use along the Stanford two-mile linear accelerator. The maximum beam loss due to scattering caused by this monitor can be made to be a small fraction of that which would be caused by a Cerenkov radiator or scintillating screen. (To be submitted to the Review of Scientific Instruments) * Work supported by the U. S. Atomic Energy...

متن کامل

Commissioning of the Detection System for a Supersonic Gas-jets Based Transverse Beam Profile Monitor

We present the commissioning results of the MicroChannel-Plate (MCP) based, ion extraction and detection system currently in use for an experimental test stand aimed at demonstrating the operation of a leastinterceptive transverse beam profile monitor based on a planar supersonic gas jet. This monitoring design features least-interceptive operation under excellent vacuum conditions and provides...

متن کامل

Optical Beam Profile Monitor for LENS Ion Source

There exists a need to conduct diagnostic tests for the LENS ion source at the Indiana University Cyclotron Facility. A pulsed proton beam of energy between 7 and 13 MeV with a peak current of 100 mA and a duty factor of 5% will be used to strike a beryllium target. In order to ensure that the beam is spread out enough as to not melt the beryllium target, a beam monitoring system will be develo...

متن کامل

Tagging of alpha particles with a large scale, high timing resolution beam profile monitor

A prototype of a new beam profile monitor with tracking and TOF capabilities for degraded beams at HISPEC/DESPEC at FAIR has been built at the Institute of Nuclear Physics at the University of Cologne [1]. The device constists of two detectors in series, each with an active area of 80x100mm. The working principle is based on secondary electrons being created by the ions passing through a thin s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Nuclear Instruments and Methods in Physics Research

سال: 2021

ISSN: ['1872-9576', '0168-9002']

DOI: https://doi.org/10.1016/j.nima.2021.165803