Turbulent flow in a curved duct with a rectangular cross-section. 4th report Pulsatile flow in a fully developed flow region.

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

PULSATILE MOTION OF BLOOD IN A CIRCULAR TUBE OF VARYING CROSS-SECTION WITH SLIP FLOW

Pulsatile motion of blood in a circular tube of varying cross-section has been developed by considering slip flow at the tube wall and the blood to be a non- Newtonian biviscous incompressible fluid. The tube wall is supposed to be permeable and the fluid exchange across the wall is accounted for by prescribing the normal velocity of the fluid at the tube wall. The tangential velocity of the fl...

متن کامل

Fluid flow and heat transfer characteristics in a curved rectangular duct using Al2O3-water nanofluid

In the present research, the laminar forced convective heat transfer and fluid flow characteristics for Al2O3-water nanofluid flowing in different bend (i.e., 180o and 90o) pipes have been investigated numerically in a three-dimensional computational domain using the finite volume technique. The effects of different pertinent parameters, such as the Reynolds number of the duct, volume fraction ...

متن کامل

Heat Transfer from a Tube Bank in Cross Flow in a Duct

An experimental investigation on heat transfer coefficient is presented from three horizontal tubes in a vertical array in a duct for 500<ReD<6000. A mass transfer measuring technique based on psychrometry chart is used to determine heat transfer coefficient. The diameter of the tubes is 11 mm each spaced 40 mm apart and in-line pitch ratio varies &#10in the range 0.055<D/W<0.22. The experimen...

متن کامل

Heat Transfer from a Tube Bank in Cross Flow in a Duct

An experimental investigation on heat transfer coefficient is presented from three horizontal tubes in a vertical array in a duct for 500<ReD<6000. A mass transfer measuring technique based on psychrometry chart is used to determine heat transfer coefficient. The diameter of the tubes is 11 mm each spaced 40 mm apart and in-line pitch ratio varies in the range 0.055<D/W<0.22. The experimenta...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series B

سال: 1987

ISSN: 0387-5016,1884-8346

DOI: 10.1299/kikaib.53.450