Tuned-Mass-Damper-Inerter Performance Evaluation and Optimal Design for Transmission Line under Harmonic Excitation
نویسندگان
چکیده
To investigate vibration control and optimal design of transmission lines with tuned-mass-damper-inerter (TMDI), the motion equation TMDI is established in paper, closed-form solutions response spectrum line displacement are derived by frequency domain analysis method. The parameters optimized fixed-point theory, performance discussed. results show that increase apparent mass ratio has a positive effect on TMDI; greatly affected limited damping ratio; both reduces peak values spectra however, blindly increasing (β > 0.2 or μ 0.4) improving compared conventional TMD, controlled can be reduced about 12%, better suppression lines.
منابع مشابه
The Multi-Degree-of-Freedom Tuned-Mass Damper for Suppression of Single-Mode Vibration Under Random and Harmonic Excitation∗
Formulas for the optimal design of single-degree-of-freedom (SDOF) tuned-mass dampers (or dynamic vibration absorbers) for SDOF structures under random and harmonic excitations have been available for many years. Whenever an absorber body is attached to a primary system, there is potential for utilization of motion in more than one degree of freedom of the body relative to the primary system. I...
متن کاملThe Two-Degree-of-Freedom Tuned-Mass Damper for Suppression of Single-Mode Vibration Under Random and Harmonic Excitation
Whenever a tuned-mass damper is attached to a primary system, motion of the absorber body in more than one degree of freedom (DOF) relative to the primary system can be used to attenuate vibration of the primary system. In this paper, we propose that more than one mode of vibration of an absorber body relative to a primary system be tuned to suppress single-mode vibration of a primary system. W...
متن کاملA RELIABILITY APPROACH TO COMPARE OPTIMAL SEISMIC DESIGNS OF MULTIPLE-TUNED-MASS-DAMPER
Passive systems are preferred tools for seismic control of buildings challenged by probabilistic nature of the input excitation. However, other types of uncertainty still exist in parameters of the control device even when optimally tuned. The present work concerns optimal design of multiple-tuned-mass-damper embedded on a shear building by a number of meta-heuristics. They include well-known g...
متن کاملReal time tuned mass damper simulation system
The major concern in the construction industry in constructing tall structures is vibration due to wind and earthquake. Tuned mass dampers are an effective and practical ways to reduce the effect of vibration in structures. This thesis presents a tool, which simulates the effect of tuned mass dampers on the structure. This tool has been proposed to form a part of the website, moment.mit.edu. Ja...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Buildings
سال: 2022
ISSN: ['2075-5309']
DOI: https://doi.org/10.3390/buildings12040435