Tune measurement in the NSLS booster synchrotron

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tune Measurement for the Cern Proton Synchrotron Booster Rings Using Dsp in Vme

The CERN PS Booster (PSB) consists of 4 superposed rings supplied with protons from a 50 MeV Linac. The proton beam is then accelerated to 1 GeV and sent either to the 26 GeV Proton Synchrotron (PS) or to the ISOLDE facility. This is carried out in a multi-cycle mode every 1.2 s. For high-intensity beams, the working-point in the tune diagram needs to be changed considerably during acceleration...

متن کامل

Synchrotron Light Monitor System for Nsls-ii

A visible synchrotron light diagnostic beam line has been designed at the NSLS2 storage ring, using the dipole radiation. The ‘cold-finger’ configuration has been selected to block the central x-rays. Beam power on the first mirror is less than 1W, no water cooling is required for the in-vacuum mirror. The beam line layout and major applications will be discussed in this paper. Two vacuum ports...

متن کامل

Observation of coherent synchrotron radiation from the NSLS VUV ring

We report the observation of multiparticle coherent emission in the very far infrared from bunched electrons in an electron storage ring. The emission occurs in quasi-periodic bursts, and only when the electron beam current exceeds a threshold value, suggesting an instability-driven modulation of the electron bunch density. For the operating conditions reported, the spectral content of the cohe...

متن کامل

The Lnls Booster Synchrotron Dipole Magnets

* [email protected] Abstract The Brazilian Synchrotron Light Laboratory (LNLS) has just constructed and commissioned a 500 MeV booster synchrotron to be used as injector for the 1.37 GeV electron storage ring. The booster has been constructed inside the storage ring, where the constraints in space are very tight. For this reason, the booster dipoles were made as small as possible, i.e., with small cu...

متن کامل

Timing System of Spring-8 Booster Synchrotron

The timing system of SPring-8 booster synchrotron generates various timing signals concerning beam injection, acceleration from 1 GeV to 8 GeV and ejection. We have improved the timing system of the synchrotron giving it better stability and flexibility. This improvement results the other merits of advanced operations, for example, storing electron beam in the synchrotron, changing the injectio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

سال: 1993

ISSN: 0168-9002

DOI: 10.1016/0168-9002(93)91161-f