Tunable phase detection sensitivity of transmitted-type guided-mode resonance sensor in a heterodyne interferometer
نویسندگان
چکیده
منابع مشابه
Pressure-tunable guided-mode resonance sensor for single-wavelength characterization.
A method of tuning a one-dimensional guided-mode resonance grating through the use of an air-pressure-responsive membrane is demonstrated here using finite-element method simulation. The device consists of a titanium dioxide (TiO(2)) grating structure embedded in a flexible polydimethylsiloxane membrane. This grating has a resonant response to TM-polarized light at a wavelength dependent upon t...
متن کاملTwo-mode heterodyne phase detection.
We present an experimental scheme that achieves ideal phase detection on a two-mode field. The two modes a and b are the signal and image band modes of an heterodyne detector, with the field approaching an eigenstate of the photocurrent Ẑ = a + b†. The field is obtained by means of a high-gain phase-insensitive amplifier followed by a high-transmissivity beam-splitter with a strong local oscill...
متن کاملOptically tunable guided-mode resonance filter.
We have demonstrated a guided-mode resonance filter (GMRF) whose properties are tunable with laser illumination through the incorporation of a nonlinear dye. Laser illumination causes a change in the refractive index of the dye-doped portion of the structure, leading to controlled tuning of the GMRF reflectance spectrum. Changes in the refractive index of dye-doped regions are proportional to t...
متن کاملGuided-Mode-Leaky-Mode-Guided-Mode Fiber Interferometer and Its High Sensitivity Refractive Index Sensing Technology
A cascaded symmetrical dual-taper Mach-Zehnder interferometer structure based on guided-mode and leaky-mode interference is proposed in this paper. Firstly, the interference spectrum characteristics of interferometer has been analyzed by the Finite Difference-Beam Propagation Method (FD-BPM). When the diameter of taper waist is 20 μm-30 μm, dual-taper length is 1 mm and taper distance is 4 cm-6...
متن کاملPolarization-based balanced heterodyne detection method in a Sagnac interferometer for precision phase measurement.
We describe a balanced heterodyne detection method for a Sagnac interferometer that uses a polarization-dependent beam splitter. The signal and the local oscillator are orthogonally polarized components of a single laser beam, permitting the detection of the signal by subtraction of two photocurrents produced in appropriate polarization projections. Using this scheme, we experimentally demonstr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Express
سال: 2014
ISSN: 1094-4087
DOI: 10.1364/oe.22.022968