Sem/eds Theoretical Stuff
Silicone based oil is heated in the boiler of the diffusion pump and the vaporized oil rises in the central tower and streams out of directional flutes directed downward in the pump throat. This allows air molecules to dissolve in the gaseous oil (gas dissolved in gas). As the oil-air mixture cools (due to water cooling coils wrapped around the pump throat) the oil condenses and returns to liqu...
متن کاملInteractive Analysis of Terabyte-sized SEM-EDS Hyperspectral Images
Scanning electron microscopy with energy-dispersive X-ray spectrometry (SEM-EDS) was used to characterize a macroscopic artifact from Peru (a Moche cast figure) [1]. A 3D hyperspectral datacube was acquired over 51.2 hours, measuring 11,520 x 9,984 pixels with 2,048 energy channels per pixel; each pixel corresponds to 900 nm in the x and y dimensions. With current technology, interacting with t...
متن کاملPyrotechnic Residues Analysis – Detection and Analysis of Characteristic Particles by Sem-eds
Many of the improvised explosive devices received at the Forensic Explosives Laboratory (FEL) contain pyrotechnic or home-made explosive mixtures as the explosive charge. Pyrotechnic residues contain a complex mixture of combustion products and unconsumed material. It has been reported that pyrotechnic residues comprise characteristic particles, similar to the formation of gunshot residue parti...
متن کاملCharacterization of pyrotechnic reaction residue particles by SEM/EDS.
Today the method commonly used for detecting gunshot residue is through the combined use of scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS). In recent years, this same methodology began to find use in detecting and characterizing pyrotechnic reaction residue (PRR) particles whether produced by explosion or burning. This is accomplished by collecting particulate sampl...
متن کاملFIB/SEM and SEM/EDS microstructural analysis of metal-ceramic and zirconia-ceramic interfaces.
Recently introduced FIB/SEM analysis in microscopy seems to provide a high-resolution characterization of the samples by 3D (FIB) cross-sectioning and (SEM) high resolution imaging. The aim of this study was to apply the FIB/SEM and SEM/EDS analysis to the interfaces of a metal-ceramic vs. two zirconia-ceramic systems. Plate samples of three different prosthetic systems were prepared in the den...