True near field versus contrast near field imaging. II. imaging with a probe
نویسندگان
چکیده
منابع مشابه
Near-field imaging with far-field data
Using the inverse diffractive grating problem as an example, we demonstrate how a super-resolution can be achieved stably by using far-field data. The idea is to place a slab of a homogeneous medium with a large index of refraction above the grating surface, and more propagating wave modes can be utilized from the far-field data which contributes to the reconstruction resolution. © 2016 Elsevie...
متن کاملTerahertz near-field imaging.
A near-field probe is described that enables high spatial resolution imaging with terahertz (THz) pulses. The spatial resolution capabilities of the system lie in the range of few microns and we demonstrate a resolution of 7 microm using broad-banded THz pulses with an intensity maximum near 0.5 THz. We present a study of the performance of the near-field probes in the collection mode configura...
متن کاملImaging the near field
In an earlier paper we introduced the concept of the perfect lens which focuses both near and far electromagnetic fields, hence attaining perfect resolution. Here we consider refinements of the original prescription designed to overcome the limitations of imperfect materials. In particular we show that a multilayer stack of positiveand negative-refractive-index media is less sensitive to imperf...
متن کاملTime as a Contrast Mechanism in Near-Field Imaging
Any modulation of a detected signal can be used as a contrast mechanism in imaging applications. Insofar as the time dependence of optical properties of imaged structures can be used to elucidate material properties, such time dependencies can provide a modulation which can then be used as a contrast mechanism in imaging. We introduce a system in which time can be used as a contrast mechanism t...
متن کاملNear - Infrared Wide - Field Imaging
We have constructed a near-infrared imaging camera which is attached to the prime focus of 105cm Schmidt telescope at Kiso Observatory. The camera is equipped with a 10401040 PtSi CSD array developed by Mitsubishi Electric Co. The combination of Kiso Schmidt and the array gives a wide eld of view of 18:4 0 18:4 0 with a reasonable spatial resolution of 1:06"=pixel. The system performances of th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Express
سال: 2007
ISSN: 1094-4087
DOI: 10.1364/oe.15.003078