Triple Immunochromatographic System for Simultaneous Serodiagnosis of Bovine Brucellosis, Tuberculosis, and Leukemia
نویسندگان
چکیده
منابع مشابه
Immunochromatographic Brucella-specific immunoglobulin M and G lateral flow assays for rapid serodiagnosis of human brucellosis.
To fulfill the need for a simple and rapid diagnostic test for human brucellosis, we used the immunochromatographic lateral flow assay format to develop two assays, one for the detection of Brucella-specific immunoglobulin M (IgM) antibodies and one for the detection of Brucella-specific IgG antibodies. The diagnostic values of these tests were examined. The tests are shown to detect acute, per...
متن کاملImmunochromatographic test for simultaneous serodiagnosis of Babesia caballi and B. equi infections in horses.
An immunochromatographic test for the simultaneous detection of Babesia caballi- and B. equi-specific antibodies (BceICT) was developed using a recombinant B. caballi 48-kDa rhoptry protein (rBc48) and a recombinant truncated B. equi merozoite antigen 2 (rEMA-2t). An evaluation of the ability of the BceICT to detect antibodies in sera from uninfected horses and experimentally infected horses sh...
متن کاملOpportunities for Improved Serodiagnosis of Human Tuberculosis, Bovine Tuberculosis, and Paratuberculosis
Mycobacterial infections-tuberculosis (TB), bovine tuberculosis (bTB), and Johne's disease (JD)-are major infectious diseases of both human and animals. Methods presently in use for diagnosis of mycobacterial infections include bacterial culture, nucleic acid amplification, tuberculin skin test, interferon-γ assay, and serology. Serological tests have several advantages over other methods, incl...
متن کاملUse of rMPB70 protein and ESAT-6 peptide as antigens for comparison of the enzyme-linked immunosorbent, immunochromatographic, and latex bead agglutination assays for serodiagnosis of bovine tuberculosis.
Current assays used to detect Mycobacterium bovis infection lack accuracy, especially for recently infected animals, or are impractical for rapid field diagnostic applications. To overcome these limitations with serological assays, a synthetic peptide derived from early secretory antigenic target 6 (ESAT6-p) and a recombinant major secreted immunogenic protein (rMPB70) of M. bovis were used in ...
متن کاملsimulation and design of electronic processing circuit for restaurants e-procurement system
the poor orientation of the restaurants toward the information technology has yet many unsolved issues in regards to the customers. one of these problems which lead the appeal list of later, and have a negative impact on the prestige of the restaurant is the case when the later does not respond on time to the customers’ needs, and which causes their dissatisfaction. this issue is really sensiti...
15 صفحه اولذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Biosensors
سال: 2019
ISSN: 2079-6374
DOI: 10.3390/bios9040115