Treatment planning for metals using an extended CT number scale
نویسندگان
چکیده
منابع مشابه
Treatment planning for metals using an extended CT number scale
Metal implants which saturate the CT number scale may require dosimetrist and physicist involvement to manually contour and assign an appropriate value to the metal for accurate dose calculation. This study investigated dose calculation based directly on extended CT scale images for different metals and geometries. The aim was to evaluate extended CT accuracy as a suitable alternative to standa...
متن کاملCT-Based Brachytherapy Treatment Planning using Monte Carlo Simulation Aided by an Interface Software
Introduction: In brachytherapy, radioactive sources are placed close to the tumor, therefore, small changes in their positions can cause large changes in the dose distribution. This emphasizes the need for computerized treatment planning. The usual method for treatment planning of cervix brachytherapy uses conventional radiographs in the Manchester system. Nowadays, because of their advantages ...
متن کاملct-based brachytherapy treatment planning using monte carlo simulation aided by an interface software
introduction: in brachytherapy, radioactive sources are placed close to the tumor, therefore, small changes in their positions can cause large changes in the dose distribution. this emphasizes the need for computerized treatment planning. the usual method for treatment planning of cervix brachytherapy uses conventional radiographs in the manchester system. nowadays, because of their advantages ...
متن کامل3-D CT for cardiovascular treatment planning.
The recently developed 64-slice CT scanner together with the use of 2-D and 3-D reconstructions can aid the cardiovascular surgeon and interventional radiologist in visualizing exact geometric relationships to plan and execute complex procedures via minimally invasive or standard approaches. Cardiac 64-slice CT considerably benefits from the high temporal and spatial resolution allowing the rel...
متن کاملEnergy Dependence of Measured CT Numbers on Substituted Materials Used for CT Number Calibration of Radiotherapy Treatment Planning Systems
INTRODUCTION For accurate dose calculations, it is necessary to provide a correct relationship between the CT numbers and electron density in radiotherapy treatment planning systems (TPSs). The purpose of this study was to investigate the energy dependence of measured CT numbers on substituted materials used for CT number calibration of radiotherapy TPSs and the resulting errors in the treatmen...