Treatment of Compression Hip Screw
نویسندگان
چکیده
منابع مشابه
Percutaneous compression plating versus compression hip screw fixation for the treatment of intertrochanteric hip fractures.
Percutaneous compression plate (PCCP) devices are used for the fixation of intertrochanteric hip fractures by a minimally invasive technique. One hundred and eight patients who underwent this procedure were retrospectively compared with 155 patients who underwent compression hip screw (CHS) fixation. The general characteristics of the two groups, including age, sex, side of injury and co-morbid...
متن کاملfixation of intertrochanteric fractures: dynamic hip screw versus locking compression plate
conclusions despite the complications of fixation with the dhs device, it remains the most successful for treatment of intertrochanteric fractures. background according to the existing literature, the dynamic hip screw (dhs) is the preferred standard for the treatment of intertrochanteric fractures. however, some surgeons use other devices such as the locking compression plate (lcp). objectives...
متن کاملA prospective, randomised study comparing the percutaneous compression plate and the compression hip screw for the treatment of intertrochanteric fractures of the hip.
Limited access surgery is thought to reduce post-operative morbidity and provide faster recovery of function. The percutaneous compression plate (PCCP) is a recently introduced device for the fixation of intertrochanteric fractures with minimal exposure. It has several potential mechanical advantages over the conventional compression hip screw (CHS). Our aim in this prospective, randomised, con...
متن کاملTreatment of comminuted subtrochanteric fractures by dynamic hip screw.
Twenty four cases of fracture of the proximal femoral shaft treated with dynamic hip screw fixation are included. All had severe comminution with subtrochanteric extensions. Dynamic hip screw provided stable osteosynthesis and helped to achieve bone union within 18 weeks in 19 of 21 followed-up cases. The anatomical configuration of the femur was maintained with minimal limb length discrepancy ...
متن کاملThe Comparison of Compression Hip Screw and Bipolar Hemiarthroplasty for the Treatment of AO Type A2 Intertrochanteric Fractures
PURPOSE The purpose of this study was to compare the outcomes of osteosynthesis using compression hip screw fixation versus bipolar hemiarthroplasty in AO type A2 intertrochanteric fractures. MATERIALS AND METHODS From March 2003 to December 2009, 89 patients were included in this study. They were treated using compression hip screws (43 cases) or bipolar hemiarthroplasty (46 cases). The mean...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Orthopedics & Traumatology
سال: 1980
ISSN: 1349-4333,0037-1033
DOI: 10.5035/nishiseisai.29.5