Transverse Section Scintigraphy by Means of Rotating Cathode Ray Tube
نویسندگان
چکیده
منابع مشابه
The Channel Multiplier Cathode-ray Tube
This paper describes a new approach to cathode-ray tube design aimed at achieving a significant depth reduction. The addressing function of the electron beam has been separated from the light generation process by a channel electron multiplier array, allowing the use of a novel deflection system based on a low-power scanning beam. Monochrome versions of the thin tube have been made with a 12" (...
متن کاملLuminance artifacts of cathode-ray tube displays for vision research.
Phosphor persistence, video bandwidth, DC restoration and high-voltage regulation affect the appearance of images presented on cathode-ray tubes (CRTs), potentially resulting in differences between nominal and actual stimuli. We illustrate these effects by measuring physical parameters of horizontal and vertical static and counter-phase flickering gratings, and we illustrate problems for vision...
متن کاملNew x-ray tube performance in computed tomography by introducing the rotating envelope tube technology.
The future demands of computed tomography imaging regarding the x-ray source can be summarized with higher scan power, shorter rotation times, shorter cool down times and smaller focal spots. We report on a new tube technology satisfying all these demands by making use of a novel cooling principle on one hand and of a novel beam control system on the other hand. Nowadays tubes use a rotating an...
متن کاملPreparation of lead oxide nanoparticles from cathode-ray tube funnel glass by self-propagating method.
This paper presents a novel process of extracting lead oxide nanoparticles from cathode-ray tube (CRT) funnel glass using self-propagating high-temperature synthesis (SHS) method. The impacts of added amount of funnel glass on the extraction ratio of lead, the lead extraction velocity and the micromorphology, as well as particle size of extracted nanoparticles were investigated. We found that s...
متن کاملA Cathode Ray Tube creates images by shooting an electron gun at wall of phosphors
This application claims an invention which was disclosed in Provisional Application Number 60/108,100, filed November 12, 1998, entitled "Desktop Projector". The benefit under 35 USC §119(e) of the United States provisional application is hereby claimed.. 5 This application is also a continuation-in-part of Serial No. 09/323,651, filed June 1, 1999, which is also a PCT International Application...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Tohoku Journal of Experimental Medicine
سال: 1972
ISSN: 0040-8727,1349-3329
DOI: 10.1620/tjem.106.175