Transverse Beam Emittance Measurement by Undulator Radiation Power Noise

نویسندگان

چکیده

Generally, turn-to-turn power fluctuations of incoherent spontaneous synchrotron radiation in a storage ring depend on the 6D phase-space distribution electron bunch. In some cases, if only one parameter is unknown, this can be determined from measured magnitude these fluctuations. Letter, we report an absolute measurement (no free parameters or calibration) small vertical emittance (5--15 nm rms) flat beam by method, under conditions, when it unresolvable conventional light size monitor.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of Electron-Beam Bunch Length and Emittance Using Shot-Noise-Driven Fluctuations in Incoherent Radiation

Longitudinal and transverse phase space information has been obtained from a statistical analysis of fluctuations in the radiation spectrum of an electron bunch. Uncorrelated shot noise fluctuations in longitudinal beam density result in incoherent radiation with a spectrum that consists of spikes, with width inversely proportional to the bunch length. Measurements were performed at l 620 nm on...

متن کامل

Using beam echo to recover transverse emittance

If the beam is injected into the ring with an offset a, it undergoes betatron oscillation. After the oscillation decoheres, the beam transverse emittance increases by ∆ε . To avoid this emittance increase one typically uses a feedback (or damper) that takes out the oscillation before it damps down. We show that using echo one can recover a fraction of ∆ε long after the beam oscillation decoheres.

متن کامل

Beam Emittance Measurement for Channel-based Ion Beam Transport

The transport of high-current beams is a crucial task in heavy-ion-beam-driven inertial fusion. Plasma-channel-based beam transport is a promising final transport concept which has been studied at the Gesellschaft für Schwerionenforschung and at the Lawrence Berkeley National Laboratory in recent years. Aspects of ion beam transport in plasma channels are studied with the Z4 beam transport expe...

متن کامل

Measurement of Coherent Off-axis Undulator Radiation as a Beam Diagnostic

* Corresponding author. Tel.: +301-405-4977. Email [email protected]. Abstract A diagnostic undulator is used to measure relative electron bunch lengths. The radiation produced by the short undulator is observed off-axis so that the beam is not interrupted. Wavelengths radiated which are longer than the bunch length are coherent and may be more intense than the shorter wavelengths by a facto...

متن کامل

Transverse emittance measurement devices for CERN injectors, present and future

The measurement of the transverse beam emittance is essential in any particle accelerator. This paper describes the problems of transverse emittance measurement for the new H LINAC being built at CERN as a replacement of the existing proton LINAC.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Physical Review Letters

سال: 2021

ISSN: ['1079-7114', '0031-9007', '1092-0145']

DOI: https://doi.org/10.1103/physrevlett.126.134802