منابع مشابه
Parametric mapping of contrasted ovarian transvaginal sonography.
The purpose of this study was to assess the accuracy of parametric analysis of transvaginal contrast-enhanced ultrasound (TV-CEUS) for distinguishing benign versus malignant ovarian masses. A total of 48 ovarian masses (37 benign and 11 borderline/malignant) were examined with TV-CEUS (Definity; Lantheus, North Billerica, MA; Philips iU22; Philips Medical Systems, Bothell, WA). Parametric image...
متن کاملTransabdominal Vs Transvaginal Sonography - Comparison in Pelvic Pathologies
Background: To compare and find diagnostic accuracy and efficacy of trans-vaginal and transabdominal sonographic techniques in female pelvic pathologies and to compare both the procedures against the gold standard of biopsy. Methods: In this comparative study two hundred patients with clinical evidence of pelvic disease of gynaecologic origin and patients with suspected ectopic pregnancy alread...
متن کاملI-59: Diagnostic Accuracy of Physical Examination,Transvaginal Sonography, RectalEndoscopic Sonography, and Magnetic ResonanceImaging to Diagnose Deep InfiltratingEndometriosis
Background: To compare the value of physical examination, transvaginal sonography (TVS), rectal endoscopic sonography (RES), and magnetic resonance imaging (MRI) for the assessment of different locations of deep infiltrating endometriosis (DIE). Materials and Methods: Ninety-two consecutive patients with clinical evidence of pelvic endometriosis. Physical examination, TVS, RES, and MRI, perform...
متن کاملTransvaginal Sonography: perception and attitude of Nigerian women
BACKGROUND To assess the attitude to and perception of transvaginal sonography (TVS) among Nigerian women of mixed educational status in order to ascertain factors that may prevent them from submitting to TVS when recommended. METHODS A Cross-sectional survey was adopted for the study. In all, one missionary, one government and eight private hospitals were enlisted. The instruments for data c...
متن کاملEarly detection of ovarian cancer with contrast enhanced transvaginal sonography
The CE-TVS differs from standard transvaginal sonography in that its inclusion of intravenous injection of ultrasound contrast with a threeminute recording of time intensity curve and its offl ine analysis. Microbubbles are prepared by shaking for 45 seconds in a specially designed vial oscillator. After an antecubital intravenous line is placed, 3 μL/kg of Defi nity (Lantheus Medical Imaging, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Medical Journal Armed Forces India
سال: 2000
ISSN: 0377-1237
DOI: 10.1016/s0377-1237(17)30160-0