Transtibial prosthetic socket pistoning: Static evaluation of Seal-In® X5 and Dermo® Liner using motion analysis system
نویسندگان
چکیده
منابع مشابه
Transtibial prosthetic socket pistoning: static evaluation of Seal-In(®) X5 and Dermo(®) Liner using motion analysis system.
BACKGROUND The method of attachment of prosthesis to the residual limb (suspension) and socket fitting is a critical issue in the process of providing an amputee with prosthesis. Different suspension methods try to minimize the pistoning movement inside the socket. The Seal-In(®) X5 and Dermo(®) Liner by Ossur are new suspension liners that intend to reduce pistoning between the socket and line...
متن کاملA clinical comparison between two common transtibial Prosthetic suspension systems
Introduction: Proper fitting of the stump inside the socket and appropriate selection of prosthetic suspension have positive effects on amputees’ satisfaction and could decrease gait deviation, skin problems, and stump atrophy. The suction sockets are commonly prescribed for transtibial amputees to have better suspension compared to the Pin and lock systems. The Seal-In® X5 (suction system) is ...
متن کاملClinical evaluation of two prosthetic suspension systems in a bilateral transtibial amputee.
The effects of Seal-In X5 and Dermo liner (Össur) on suspension and patient's comfort in lower limb amputees are unclear. In this report, we consider the case of a 51-yr-old woman with bilateral transtibial amputation whose lower limbs were amputated because of peripheral vascular disease. The subject had bony and painful residual limbs, especially at the distal ends. Two prostheses that used S...
متن کاملComparative Study between Dermo, Pelite, and Seal-In X5 Liners: Effect on Patient's Satisfaction and Perceived Problems
PURPOSE This study aimed to compare the effect of satisfaction and perceived problems between Pelite, Dermo with shuttle lock, and Seal-In X5 liners on the transtibial amputees. MATERIAL AND METHODS A total of thirty transtibial amputees (17 male, 13 female) volunteered to take part in this research. Two prostheses were fabricated for each participant. Prosthetic Evaluation Questionnaire (PEQ...
متن کاملTranstibial prosthetic suspension: less pistoning versus easy donning and doffing.
Poor suspension increases slippage of the residual limb inside the socket during ambulation. The main purpose of this article is to evaluate the pistoning at the prosthetic liner-socket interface during gait and assess patients' satisfaction with two different liners. Two prostheses with seal-in and locking liners were fabricated for each of the 10 subjects with transtibial amputation. The Vico...