منابع مشابه
PERCUTANEOUS TRANSTHORACIC BIOPSY USING TRU-CUT NEEDLE
Biopsies of thoracic lesions guidance. 22 of the 1 12 lesions were mediastinal and 83 were pleuroparenchymal. A large-bore 14-gauge Tru-cut needle was used in all patients. Adequate specimens for histologic examination were obtained in 98%. The overall accuracy was 91 % with 9% false negative and no false positive diagnoses. Despite the large size of the needle, the total number of complic...
متن کاملDiagnostic yield of transbronchial needle aspiration--analysis of 30 cases.
BACKGROUND In our clinical set up transbonchial needle aspiration of lymph node and parenchymal lesions is an underutilized technique. This study was done to highlight the usefulness of this technique in the pulmonologists armamentarium. METHODS Thirty procedures were performed on patients with intrathoracic lymphadenopathy or parenchymal lung lesions in this study from October, 2006 to April...
متن کاملThe role of transthoracic needle biopsy.
CHEST I 95 I 2 I FEBRUARY, 1989 483 oppose it duringlate inspiration with W (is, W 5 = W . and = 0) was a reasonable approximation of this ideal system (Fig 2B). Subsequent human subject studies were performed in part to test the mechanical model results which were based on this reasoning. It is possible that another PS system which initiates, maintains and! or terminates pressure sooner would ...
متن کاملpercutaneous transthoracic biopsy using tru-cut needle
biopsies of thoracic lesions guidance. 22 of the 1 12 lesions were mediastinal and 83 were pleuroparenchymal. a large-bore 14-gauge tru-cut needle was used in all patients. adequate specimens for histologic examination were obtained in 98%. the overall accuracy was 91 % with 9% false negative and no false positive diagnoses. despite the large size of the needle, the total number of complication...
متن کاملCT-guided transthoracic fine needle aspiration of pulmonary lesions: accuracy and complications in 134 cases.
The aim of this study was to perform a prospective evaluation of the effectiveness of computed tomography (CT)-guided transthoracic fine needle aspiration (TFNA) in the diagnosis of pulmonary lesions and to determine the complication rate of this procedure. A prospective review was conducted of 134 patients who underwent CT-guided TFNA at our center between December 2003 and August 2005. All fi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Tuberculosis and Respiratory Diseases
سال: 1983
ISSN: 1738-3536,2005-6184
DOI: 10.4046/trd.1983.30.4.205