Transient Stability Assessment for Current Constrained and Unconstrained Fault Ride-Through in Virtual Oscillator Controlled Converters

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Selection of Resistive and Inductive Superconductor Fault Current Limiters Location Considering System Transient Stability

Superconductor fault current limiter (SFCL) is an effective device to suppress high fault currents. This paper presents a comparative study of resistive and inductive fault current limiters from transient stability point of view.  Appropriate location and type of the limiters in a HV substation is selected by a qualitative approach based on the equal area criterion. Study system is simulated by...

متن کامل

Unconstrained and Constrained Fault-Tolerant Resource Allocation

First, we study the Unconstrained Fault-Tolerant Resource Allocation (UFTRA) problem (a.k.a. FTFA problem in [19]). In the problem, we are given a set of sites equipped with an unconstrained number of facilities as resources, and a set of clients with setR as corresponding connection requirements, where every facility belonging to the same site has an identical opening (operating) cost and ever...

متن کامل

selection of resistive and inductive superconductor fault current limiters location considering system transient stability

superconductor fault current limiter (sfcl) is an effective device to suppress high fault currents. this paper presents a comparative study of resistive and inductive fault current limiters from transient stability point of view.  appropriate location and type of the limiters in a hv substation is selected by a qualitative approach based on the equal area criterion. study system is simulated by...

متن کامل

Coordination between Fault-Ride-Through Capability and Over-current Protection of DFIG Generators for Wind Farms

Fault Ride-Through (FRT) capabilities set up according to the grid codes may affect the performance of related protective elements during fault periods. Therefore, in this paper the coordination between the FRT capability and over-current protection of DFIG Wind Generators in MV networks is investigated. Simulation test cases using MATLAB-Simulink are implemented on a 365-MW wind farm in AL-Zaa...

متن کامل

Fault Ride-through Capability Enhancement of Voltage Source Converter-High Voltage Direct Current Systems with Bridge Type Fault Current Limiters

This paper proposes the use of bridge type fault current limiters (BFCLs) as a potential solution to reduce the impact of fault disturbance on voltage source converter-based high voltage DC (VSC-HVDC) systems. Since VSC-HVDC systems are vulnerable to faults, it is essential to enhance the fault ride-through (FRT) capability with auxiliary control devices like BFCLs. BFCL controllers have been d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Journal of Emerging and Selected Topics in Power Electronics

سال: 2021

ISSN: 2168-6777,2168-6785

DOI: 10.1109/jestpe.2021.3080236