Transient Simulation Analysis of Doubly-fed Wind Power Generation System
نویسندگان
چکیده
منابع مشابه
Review on Wind Power Generation With Doubly Fed Induction Generator
This paper presents the review of the Doubly fed Induction Generator (DFIG) based Wind Energy Conversion System (WECS). Basically the various challenges of the grid connected DFIG based wind turbine has been highlighted in this review. Nonlinear model of wind turbine with DFIG configuration are explained and a 1.2 MW, 50 Hz, 6 pole DFIG simulated using MATLAB/SIMULINK. Some important control is...
متن کاملOptimal Operation of Doubly-fed Induction Generator used in a Grid-Connected Wind Power System
In this paper, a wind power system based on a doubly-fed induction generator (DFIG) is modeled and simulated. To guarantee high-performance control of the powers injected into the grid by the wind turbine, five intelligent super-twisting sliding mode controllers (STSMC) are used to eliminate the active power and current ripples of the DFIG. The STSMC controller is a high-order sliding mode cont...
متن کاملTransient Analysis of Doubly Fed Wind Power Induction Generator Using Coupled Field-Circuit Model
The paper presents the transient analysis of a 1.7 MVA wind-power doubly fed induction generator (DFIG) connected to the network and controlled by modified direct torque control during power system disturbances. The finite element model of DFIG is coupled with circuit models of frequency converter, transformer, network and control part in Matlab-Simulink. The transient currents and electromagne...
متن کاملAdaptive Nonlinear Control of Doubly-fed Induction Machine in Wind Power Generation
This paper presents an adaptive nonlinear controller for Doubly-Fed Induction Generator (DFIG) in wind power generation. The control objective is to extract the maximum power (Maximum Power Point Tracking) and have a specified reactive power at the generator terminal despite the variable wind speed and the unknown mechanical parameters and mechanical torque. To achieve such a decoupled control,...
متن کاملTransient Behavior of Doubly Fed Induction Generator Using Simulink Model in Wind Energy Conversion System
In this paper, transient behaviours of the Doubly Fed Induction Generator using Simulink model is demonstrated. A mathematical model based on d-q transformation i.e. stator phase currents, rotor currents, stator flux linkages,rotor flux linkages ,instantaneous power electromagnetic torque is also presented. In this paper 9 MW wind farm consisting of six 1.5 MW wind turbines connected to a 25 kV...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: DEStech Transactions on Engineering and Technology Research
سال: 2017
ISSN: 2475-885X
DOI: 10.12783/dtetr/iceeac2017/10713