Transient behaviour and rate effects in resistive detectors

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two-Parameter Analysis of the Temporal Behaviour of Resistive Detectors

The biggest constraint in the RPCs operation is the drop of their efficiency with the counting rate, consequence of charge gain decrease. This effect is normally attributed to the voltage drop on the dielectrics, although not supported by quantitative measurement. In this work we present the first results of a two-parameter analysis of the charge pulse height time variation from a cylindrical r...

متن کامل

the effects of speech rate,prosodic features, and blurred speech on iranian efl learners listening comprehension

کلید واژه ها به زبان انگلیسی: effect of speech rate on listening comprehension, blurred speech,segmental and suprasegmental features,authentic speech,intelligibility, discrimination, omission, assimilation چکیده: سرعت مطالب شنیداری در کلام پیوسته بطور کلی همواره کابوسی بوده برای یادگیرنده های زبان دوم و بالاخص برای شنوندگان ایرانی. علی رغم عقل سلیم که کلام با سرعت کندتری فعالیتهای درک مطلب شن...

15 صفحه اول

Rate effects in a proportional counter with resistive cathode

In this work, the rate effects associated with the gain of detectors with resistive electrodes are considered. To study these effects it was decided to use the classical proportional counter geometry, with a cylindrical glass tube as the cathode, rather than parallel plate devices. Indeed, the generality of the information obtained is not affected and the cylindrical proportional counter geomet...

متن کامل

Characterization and Calibration of Large Area Resistive Strip Micromegas Detectors

Resistive strip Micromegas detectors have been tested extensively as small detectors of about 10 x 10 cm2 in size and they work reliably at high rates of 100 kHz/cm2 and above. Tracking resolution well below 100μm has been observed for 100 GeV muons and pions. Micromegas detectors are meanwhile proposed as large area muon precision trackers of 2-3 m2 in size. To investigate possible differences...

متن کامل

patterns and variations in native and non-native interlanguage pragmatic rating: effects of rater training, intercultural proficiency, and self-assessment

although there are studies on pragmatic assessment, to date, literature has been almost silent about native and non-native english raters’ criteria for the assessment of efl learners’ pragmatic performance. focusing on this topic, this study pursued four purposes. the first one was to find criteria for rating the speech acts of apology and refusal in l2 by native and non-native english teachers...

15 صفحه اول

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

سال: 1998

ISSN: 0168-9002

DOI: 10.1016/s0168-9002(98)00825-0