Transformer Winding Deformation Detection Based on BOTDR and ROTDR
نویسندگان
چکیده
منابع مشابه
FEM based Reactance Computation for Transformer Winding Deformation Detection
Leakage reactance is one of the most important specifications in transformer that has significant impact on its overall design. Variation in leakage reactance serves as a diagnostic measure to indicate mechanical integrity of power transformers before and after a short circuit test that demonstrates mechanical strength of transformer windings. This paper presents an approach for leakage reactan...
متن کاملImproved Detection Sensitivity with Combined WPT and HHT for Power Transformer Winding Deformation Analysis
The success of health monitoring and condition assessment of power transformers based on winding current signature analysis lies on proper extraction of features. The extraction of features in turn depends on appropriate signal processing methods. Fourier based signal analysis provides only frequency information and also suitable only for stationary signals. In this paper we present a combined ...
متن کاملA Feasible Solution to Distinguish the Transformer Winding Deformation from Insulation Characteristic Impacts on FRA Spectrum
Frequency Response Analysis (FRA) is popular technique which has been used since the last decade as a diagnostic method for transformers. However, accurate interpretation of FRA measurements is still challenging. Recent studies reveal that apart from winding deformation, FRA data can also be influenced by moisture variation in transformer paper insulation. Hence, a specific transformer’s model ...
متن کاملDetection of transformer winding deformations based on the transfer function—measurements and simulations
Improvement of diagnostic methods for both power and distribution transformers is crucial considering the part they play in electrical networks as well as their cost. Transfer function based testing of transformers is one of the methods that has been introduced recently. This method enables the identification of winding deformations resulting from the short circuit currents and winding dislocat...
متن کاملTransformer Models for Detection of Incipient Internal Winding Faults
A method of modeling internal turn-to-earth and turn-toturn faults in distribution transformer is discussed in this paper. The models are entirely compatible with the Alternative Transients Program(ATP). The simulation of the faults is based on known leakage factors between the various coils of the transformer. These leakage factors are evaluated by using a simple method implemented in this pap...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Sensors
سال: 2020
ISSN: 1424-8220
DOI: 10.3390/s20072062