Transformation of Dynamic Loads into Equivalent Static Load based on the Stress Constraint Conditions
نویسندگان
چکیده
منابع مشابه
the effect of taftan pozzolan on the compressive strength of concrete in the environmental conditions of oman sea (chabahar port)
cement is an essential ingredient in the concrete buildings. for production of cement considerable amount of fossil fuel and electrical energy is consumed. on the other hand for generating one tone of portland cement, nearly one ton of carbon dioxide is released. it shows that 7 percent of the total released carbon dioxide in the world relates to the cement industry. considering ecological issu...
Equivalent Static Wind Loads for Buffeting Response
In current design practice, the dynamic wind loads are described in terms of the equivalent static wind loads based on the gust response factor. This approach results in a distribution of the equivalent static loading similar to the mean static wind load distribution, which may not always be a physically meaningful and realistic load description. In this paper, the equivalent static load repres...
متن کاملEvaluation of Equivalent Static Wind Loads on Buildings
Wind loads on buildings can be quantified through synchronous measurements of pressure over building model surfaces or by high frequency force balance (HFFB) measurements. Although this loading information can be directly utilized for building design applications, current design practice often requires the transformation of dynamic wind loading to the equivalent static wind loads (ESWLs). This ...
متن کاملAlongwind Static Equivalent Wind Loads and Responses of Tall Buildings. Part I: Unfavorable Distributions of Static Equivalent Wind Loads
Although on the same theoretical basis, the current standards of major countries have set out two evidently different distributions of along-wind static equivalent wind loads, one is the same as the mean wind force and the other is the same as the first mode shape, on tall buildings. In this paper, the fluctuating static equivalent wind load is evaluated as mean, background and resonant compone...
متن کاملEquivalent Static Wind Loads on Buildings: New Model
In current design practice, spatiotemporally varying wind loads on buildings are modeled as equivalent static wind loads. This loading description serves as pivotal information for estimating response under the combined action of wind and other loads. This paper presents a framework for evaluating the equivalent static wind load for any given peak response of buildings with uncoupled responses ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Computational Structural Engineering Institute of Korea
سال: 2013
ISSN: 1229-3059
DOI: 10.7734/coseik.2013.26.2.165