Transfer function technique for impedance and absorption measurements in an impedance tube using a single microphone

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

the feasibility of using impedance tube with two microphones and sound absorption coefficient measurement of iranian-made materials using transfer function method

background: sound is one of the most important factors threatening workers’ health. the most efficient and practical method for controlling noise pollution is the use of sound-absorbing materials. impedance tube with two microphones is used to determine the sound absorption coefficients and should be tested periodically for accuracy and efficiency. the purpose of present study was assessing the...

متن کامل

An Adaptive Impedance Controller for Robot Manipulators

A desired dynamic behavior of constrained manipulators can be achieved by means of impedance control and various implementations of fixed controllers have been proposed. In this paper, and adaptive implementation is presented as an alternative to reduce the design sensitivity due to manipulator mismatch. The adaptive controller globally achieves the impedance objective for the nonlinear dynamic...

متن کامل

Impedance-type measurements using XPS

An impedance type of measurement using X-ray photoelectron spectroscopy is applied for probing charging/discharging dynamics of a sample containing Rb deposited on a SiO2/Si substrate containing an octadecyltrichlorosilane (OTS) bilayer coating. The OTS bilayer coatings have possible use as antirelaxationwall coatings for alkali atom vapor cells inminiaturized instruments such as chip-scale ato...

متن کامل

A new correction technique for measuring respiratory impedance through an endotracheal tube.

Measurement of respiratory impedance (Zrs) in intubated patients requires corrections for flow-dependent resistance and air compression inside the endotracheal tube (ET). The purpose of this study was to test a new correction technique for these effects. We therefore studied 110 patients in two conditions: breathing normally (C1), or breathing through an ET placed at the mouth (C2). In C1, we m...

متن کامل

A Method of Function Space for Vertical Impedance Function of a Circular Rigid Foundation on a Transversely Isotropic Ground

This paper is concerned with investigation of vertical impedance function of a surface rigid circular foundation resting on a semi-infinite transversely isotropic alluvium. To this end, the equations of motion in cylindrical coordinate system, which because of axissymmetry are two coupled equations, are converted into one partial differential equation using a method of potential function. The g...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Journal of the Acoustical Society of America

سال: 1986

ISSN: 0001-4966

DOI: 10.1121/1.394050