Transcutaneous measurement of blood velocity profiles and flow
نویسندگان
چکیده
منابع مشابه
Estimation of Microcirculatory Blood Flow Velocity Profiles
An approach to estimate blood flow cross-sectional velocity profiles in intravital microscopy videos of post-capillary venules is proposed. Given an image sequence, the cross-section upon which the velocity profile is to be estimated is manually chosen. The velocity of each streamline, assumed perpendicular to the chosen cross-section, is estimated separately from other streamlines, except for ...
متن کاملcomparison of blood flow velocity changes in posterior cerebral artery measured with transcranial doppler sonography in migraineurs with visual aura and normal persons after photostimulation
چکیده ندارد.
15 صفحه اولMeasurement of velocity profiles in multiphase flow using a multi-electrode electromagnetic flow meter
This paper describes an electromagnetic flow meter for velocity profile measurement in single phase and multiphase flows with non-uniform axial velocity profiles. A Helmholtz coil is used to produce a near-uniform magnetic field orthogonal to both the flow direction and the plane of an electrode array mounted on the internal surface of a non-conducting pipe wall. Induced voltages acquired from ...
متن کاملDevelopment of a Miniaturized Fiber-optic LDV Sensor for Local Blood Velocity Measurement Local Velocity and Flow Profile Measurement of Pulsatile Blood Flow Modeled in Humans
131 DOI: 10.5963/BER0203002 Development of a Miniaturized Fiber-optic LDV Sensor for Local Blood Velocity Measurement Local Velocity and Flow Profile Measurement of Pulsatile Blood Flow Modeled in Humans Shimpei Kohri, Tsutomu Tajikawa, Kenkichi Ohba Department of Medical Engineering, Aino University 4-5-4, Higashiohda, Ibaraki city, Osaka 567-0012 Japan Department of Mechanical Engineering, Ka...
متن کاملNoninvasive measurement of velocity profiles and blood flow in the common carotid artery by pulsed Doppler ultrasound.
A computer-controlled 14-channel pulsed Doppler ultrasound instrument was used as a noninvasive means to evaluate instantaneous velocity profiles and flow in the comlon carotid arteries of 22 healthy persons and in 22 patients. Of the later, 13 had severe obstructions of the extracranial portion of the carotid artery, four had obstruction of the intracranial portion, and five had severe aortic ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Cardiovascular Research
سال: 1973
ISSN: 0008-6363
DOI: 10.1093/cvr/7.5.703