Traction behavior of soccer shoe stud designs under different game-relevant loading conditions
نویسندگان
چکیده
منابع مشابه
Finite Element Analysis of Different Hip Implant Designs along with Femur under Static Loading Conditions
Background: The hip joint is the largest joint after the knee, which gives stability to the whole human structure. The hip joint consists of a femoral head which articulates with the acetabulum. Due to age and wear between the joints, these joints need to be replaced with implants which can function just as a natural joint. Since the early 19th century, the hip joint arthroplasty has evolved, a...
متن کاملSilk Persian Carpet under Loading in Different Environmental Conditions
In this research, an apparatus was designed and constructed in order to simulate the storage behavior of hand-woven carpet under different environmental conditions. Silk hand-woven carpet (“Gom”) with 115×75 cm dimensions and 102×97 knot per 10 cm was selected and then inserted into the packing simulator with two different laying configurations including flat and folded....
متن کاملBehaviour of Corroded Stud Shear Connectors under Fatigue Loading
Experimental investigation was conducted on corroded composite push-out specimens to study the behavior of shear studs subjected to fatigue loading. A total of eight standard EC4 push-out specimens were tested. The expected corrosion rate of test specimens ranged from 0 to 50%. The main purpose of these tests was to determine the fatigue life and the reduction effect caused by the corrosion on ...
متن کاملStatic Deflection of Hinged-Hinged piezoelectric Multilayer Beam Under Different Loading Conditions
In this paper at first introduced constituent equations for piezoelectric and then by the help of this equations, internal energy of hinged-hinged piezoelectric multilayer beam was computed. Then by the principle of minimum potential energy and Rayleigh -Ritz method the bending curvature equation of hinged-hinged piezoelectric multilayer beam under concentrated moment, concentrated force, unifo...
متن کاملEffect of Different Loading Conditions
It has previously been demonstrated that predictable changes occur in mitral flow velocities under different loading conditions. The purpose of this study was to relate changes in pulmonary venous and mitral flow velocities during different loading conditions as assessed by transesophageal echocardiography in the operating room. Nineteen patients had measurements of hemodynamics, that is, mitra...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Procedia Engineering
سال: 2010
ISSN: 1877-7058
DOI: 10.1016/j.proeng.2010.04.066