Tracing Resistances of Anion Exchange Membrane Water Electrolyzer during Long-term Stability Tests
نویسندگان
چکیده
منابع مشابه
Real-Time Microscopic Monitoring of Flow, Voltage and Current in the Proton Exchange Membrane Water Electrolyzer
Looking for alternative energy sources has been an inevitable trend since the oil crisis, and close attentioned has been paid to hydrogen energy. The proton exchange membrane (PEM) water electrolyzer is characterized by high energy efficiency, high yield, simple system and low operating temperature. The electrolyzer generates hydrogen from water free of any carbon sources (provided the electron...
متن کاملAnion Exchangers for Water Treatment: Ion Exchange
ation sciences is the puriRcation and recovery of solvents especially from HPLC and GPC usage. There is a range of equipment supplied for recycling of solvents and useful sources of information can be found on the internet, for example the web pages for B/R Instruments and Recycling Sciences are included in the Further Reading. The applications of distillation in analysis are widespread, with t...
متن کاملIntestinal anion exchange in teleost water balance.
Simultaneous measurements of all major electrolytes including HCO3(-) and H+ as well as water demonstrated that fluids absorbed by the anterior intestine of the marine gulf toadfish under in vivo-like conditions on an overall net basis are hypertonic at 380 mOsm and acidic ([H+] = 27 mM). This unusual composition of fluids absorbed across the intestinal epithelium is due to the unusual intestin...
متن کاملLong-Term Stability of a Cellulose-Based Glucose Oxidase Membrane
A cellulose-based glucose oxidase membrane was prepared on a glassy carbon (GC) electrode. The current response of the electrode to glucose was measured by applying a potential of 1.0 V vs. Ag/AgCl on the base GC and was proportional to the concentration of glucose up to 1 mM. The long-term stability of the electrode was examined by measuring the daily glucose response. Over four months, the re...
متن کاملThermodynamic analysis of anion exchange during heteroepitaxy
A thermodynamic approach is presented to assess the extent of anion exchange reactions during the heteroepitaxy (molecular beam epitaxy) of dissimilar anion III–V compound semiconductor structures. It is shown that the extent of anion exchange can be predicted by the change in the Gibbs free energy. Bond strength changes can only be used as a guide in comparing the relative tendency for exchang...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Electrochemical Science and Technology
سال: 2021
ISSN: 2093-8551,2288-9221
DOI: 10.33961/jecst.2021.00094