Tracheal tube biofilm removal through a novel closed-suctioning system: an experimental study

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tracheal tube biofilm removal through a novel closed-suctioning system: an experimental study.

BACKGROUND Tracheal tube biofilm develops during mechanical ventilation. We compared a novel closed-suctioning system vs standard closed-suctioning system in the prevention of tracheal tube biofilm. METHODS Eighteen pigs, on mechanical ventilation for 76 h, with P. aeruginosa pneumonia were randomized to be tracheally suctioned via the KIMVENT* closed-suctioning system (control group) or a no...

متن کامل

Effect of tracheal suctioning on aspiration past the tracheal tube cuff in mechanically ventilated patients

UNLABELLED BACKGROUND This clinical study evaluated the effect of a suctioning maneuver on aspiration past the cuff during mechanical ventilation. METHODS Patients intubated for less than 48 hours with a PVC-cuffed tracheal tube, under mechanical ventilation with a PEEP ≥5 cm H2O and under continuous sedation, were included in the study. At baseline the cuff pressure was set at 30 cm H2O. ...

متن کامل

Dissemination of respiratory secretions during tracheal tube suctioning in an intensive care unit.

Most intensive care patients require frequent tracheal toilet, a procedure usually performed by suctioning the tracheal tube. Such procedures often result in the production and dissemination of droplets. We measured the distance visible droplets disseminated during tracheal tube suctioning of patients in an adult surgical intensive care unit. Fifty consecutive suction procedures in 14 patients ...

متن کامل

Case study involving suctioning of an electromyographic endotracheal tube.

The electromyographic endotracheal tube (EMG-ETT) is a relatively new tool used to measure integrity of the vocal cord structures during surgery. We describe a case in which an EMG-ETT was inserted for the operative period but not replaced with an ETT during the immediate postoperative period. Intensive care unit nurses had difficulty suctioning the EMG-ETT. The patient was not provided the pul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: British Journal of Anaesthesia

سال: 2015

ISSN: 0007-0912

DOI: 10.1093/bja/aev340