Trace Level Arsenic Quantification through Cloud Point Extraction: Application to Biological and Environmental Samples
A sensitive solvent-free extraction protocol for the quantification of arsenic at trace level has been described. It is based on the reaction of arsenic (V) with molybdate in acidic medium in presence of antimony (III) and ascorbic acid as a reducing agent to form a blue-colored arsenomolybdenum blue complex. The complex has been extracted into surfactant phase using Triton X-114, and its absor...
متن کاملMicelle Mediated Trace Level Sulfide Quantification through Cloud Point Extraction
A simple cloud point extraction protocol has been proposed for the quantification of sulfide at trace level. The method is based on the reduction of iron (III) to iron (II) by the sulfide and the subsequent complexation of metal ion with nitroso-R salt in alkaline medium. The resulting green-colored complex was extracted through cloud point formation using cationic surfactant, that is, cetylpyr...
متن کاملPoisoning by Red Arsenic
On the following morning they all seemed to get better, except one or two who complained of headache, burning sensation of the body and constantthirst. These symptoms were easily relieved by the administration of dilute Sulphuric acid in ten drop doses in an ounce of water every 2 hours. On the 6th July they were all discharged from the hospital cured. The history of the above case was the foll...
متن کاملBromination and Dehydrobromination Studies on Some CIS-4a-Methyl-Decaline-2,7-Diones
Results of the bromination and dehydrobromination of several angular methylated decalindiones are described. The key reaction, base-induced cyclization of the monobromo keto ester (3), and the dibromo ketone (4), leads to the formation of tricyclic systems (6) and (9) respectively.
متن کاملTrace-Level Reuse
Trace-level reuse is based on the observation that some traces (dynamic sequences of instructions) are frequently repeated during the execution of a program, and in many cases, the instructions that make up such traces have the same source operand values. The execution of such traces will obviously produce the same outcome and thus, their execution can be skipped if the processor records the ou...