Toward a Robust Estimation of Respiratory Rate From Pulse Oximeters

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Standard pulse oximeters can be used to monitor respiratory rate.

BACKGROUND One of the most important limitations of standard pulse oximeters is the inability to detect changes in respiratory rate until oxygenation is affected. This study sought to determine if analysis of the plethysmogram by wavelet transforms would enable the determination of changes in respiratory rate at an earlier stage. METHODS Ten healthy adult volunteers were monitored, breathing ...

متن کامل

Bias and precision of pulse oximeters and arterial oximeters.

We evaluated measurements of oxygen saturation from four noninvasive pulse oximeters, and two conventional arterial oximeters. Simultaneous measurements were obtained on each instrument on three different occasions in five healthy subjects breathing gas with an FIO2 of 1.00, 0.50, 0.21, 0.17, 0.15, 0.13 and 0.11. Mean bias relative to the sum of oxy-, carboxy-, and methemoglobins ranged from -0...

متن کامل

Accuracy and precision of fourteen pulse oximeters.

Two sets of seven pulse oximeters (Criticare CSI-502; Nellcor-N200; Datex-Satlite; Physio-Control-Lifestat 1600; Critikon-Oxyshuttle; Ohmeda-Biox 3700; Ohmeda-Biox 3740; Radiometer-Oxi; Spectramed-Pulsat; Kontron-7840; Biochem-Ox2000; Invivo-4500; Engström-EOS; Novametrix-505) were studied in two groups of eight healthy subjects, aged 26-50 yrs. The transcutaneous oxygen saturation (SpO2) was c...

متن کامل

Toward an estimation of the clarinet reed pulse from instrument

9 In this work, a technique is presented for estimating the reed pulse from the pressure signal recorded at 10 the bell of a clarinet during performance. The reed pulse is a term given to the typically periodic 11 sequence of bore input pressure pulses, a signal related to the volume flow through a vibrating reed by 12 the characteristic impedance of the aperture to the bore. The problem is sim...

متن کامل

Fast and Robust Real-Time Estimation of Respiratory Rate from Photoplethysmography

Respiratory rate (RR) is a useful vital sign that can not only provide auxiliary information on physiological changes within the human body, but also indicate early symptoms of various diseases. Recently, methods for the estimation of RR from photoplethysmography (PPG) have attracted increased interest, because PPG can be readily recorded using wearable sensors such as smart watches and smart b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Biomedical Engineering

سال: 2017

ISSN: 0018-9294,1558-2531

DOI: 10.1109/tbme.2016.2613124