Totem-Pole Power-Factor-Correction Converter under Critical-Conduction-Mode Interleaved Operation

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Totem-Pole Power-Factor-Correction Converter under Critical-Conduction-Mode Interleaved Operation

This paper proposes a new power-factor-correction (PFC) topology, and explains its operation principle, its control mechanism, related application problems followed by experimental results. In this proposed topology, critical-conduction-mode (CRM) interleaved technique is applied to a bridgeless PFC in order to achieve high efficiency by combining benefits of each topology. This application is ...

متن کامل

An Interleaved Totem-Pole Power Factor Correction Converter

This paper explains about basic working principles, implementation problems, and experimental results of a new power factor correction (PFC) topology. In this proposed topology, a totem-pole boost PFC circuit that works under interleaved critical-conduction-mode (CRM) condition is presented. The circuit is developed towards high efficiency, high performance, lowcost, simple control scheme, and ...

متن کامل

Predictive Control of a Series-Interleaved Multi-Cell Three-Level Boost Power Factor Correction Converter

This paper presents a new predictive power-factorcorrection (PFC) controller for series-interleaved three-level boost (TLB) converters. Compared to the state-of-the-art TLB PFC controllers, where a two-cycle prediction and a detection of an operating region are necessary, the proposed controller achieves a low total harmonic distortion of the input current by using a single equation to predict ...

متن کامل

Modified Bi-directional AC/DC Power Converter with Power Factor Correction

Most existing power  converters and industrial motor drive systems draw non-sinusoidal currents from the supply. Non-sinusoidal currents contained harm harmonics disturb the power supply which it causes serious concern for reliability. Other equipments that use the same power supply are adversely affected. This paper suggests the operation and performance of a new modified AC/DC converter that ...

متن کامل

Isolated Three-Phase Rectifier Using a Sepic DC-DC Converter in Continuous Conduction Mode For Power Factor Correction

This paper presents an analysis of a three-phase rectifier with high power factor using a Sepic DC-DC converter operating in continuous conduction mode (CCM). The structure is particularly simple and robust. Its main features are: one power processing stage, which can operate as step-down or step-up voltage, lower harmonic distortion in the line current and natural isolation. The converter work...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEICE Transactions on Communications

سال: 2010

ISSN: 0916-8516,1745-1345

DOI: 10.1587/transcom.e93.b.2250