Total‐Absorption Scintillation Counter for High‐Energy Photons
نویسندگان
چکیده
منابع مشابه
The Scintillation Counter
The development of detectors for both counting and measuring the energy of particles and photons has played an important role in the evolution of nuclear physics. In this experiment, you will be introduced to one such detector the scintillation counter which is particularly suitable for detecting γ-ray photons. You will use it to observe the energy spectrum of γ-rays from several nuclei and stu...
متن کاملScintillation Proximity Assay on the TopCount Microplate Scintillation Counter
The TopCountTM Microplate Scintillation Counter quantitates radioisotopes by liquid scintillation counting in standard microplate formats. Assays that previously had to be transferred from microplates to vials or to non-standard formats for counting can now be quantitated directly in microplates. TopCount can count up to 12 samples simultaneously with performance comparable to that of discrete ...
متن کاملNonabsorbing high-efficiency counter for itinerant microwave photons
Bixuan Fan,1 Göran Johansson,2 Joshua Combes,3 G. J. Milburn,1 and Thomas M. Stace1,* 1Center for Engineered Quantum Systems, School of Mathematics and Physics, The University of Queensland, St Lucia, Queensland 4072, Australia 2Microtechnology and Nanoscience, Chalmers University of Technology, S-41296 Göteborg, Sweden 3Center for Quantum Information and Control, University of New Mexico, Albu...
متن کاملThe gas proportional scintillation counter / microstrip gas chamber hybrid detector
The gas proportional scintillation counter/microstrip gas chamber (GPSC/MSGC) hybrid detector for X-ray spectrometry is described. The detector uses a CsI-coated microstrip plate placed in direct contact with the gas-filling as the photosensor readout for the GPSC scintillation substituting for the photomultiplier tube (PMT). Usable photosensor maximum gain is limited by optical positive feedba...
متن کاملCounting Aqueous Samples with the TopCount Microplate Scintillation Counter
The TopCountTM Microplate Scintillation Counter quantitates radioisotopes by liquid scintillation counting in standard microplate formats. Assays that previously had to be transferred from microplates to vials or to non-standard formats for counting can now be quantitated directly in microplates. TopCount can count up to 12 samples simultaneously with performance comparable to that of discrete ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Review of Scientific Instruments
سال: 1962
ISSN: 0034-6748,1089-7623
DOI: 10.1063/1.1717948