Total‐Absorption Scintillation Counter for High‐Energy Photons

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Scintillation Counter

The development of detectors for both counting and measuring the energy of particles and photons has played an important role in the evolution of nuclear physics. In this experiment, you will be introduced to one such detector the scintillation counter which is particularly suitable for detecting γ-ray photons. You will use it to observe the energy spectrum of γ-rays from several nuclei and stu...

متن کامل

Scintillation Proximity Assay on the TopCount Microplate Scintillation Counter

The TopCountTM Microplate Scintillation Counter quantitates radioisotopes by liquid scintillation counting in standard microplate formats. Assays that previously had to be transferred from microplates to vials or to non-standard formats for counting can now be quantitated directly in microplates. TopCount can count up to 12 samples simultaneously with performance comparable to that of discrete ...

متن کامل

Nonabsorbing high-efficiency counter for itinerant microwave photons

Bixuan Fan,1 Göran Johansson,2 Joshua Combes,3 G. J. Milburn,1 and Thomas M. Stace1,* 1Center for Engineered Quantum Systems, School of Mathematics and Physics, The University of Queensland, St Lucia, Queensland 4072, Australia 2Microtechnology and Nanoscience, Chalmers University of Technology, S-41296 Göteborg, Sweden 3Center for Quantum Information and Control, University of New Mexico, Albu...

متن کامل

The gas proportional scintillation counter / microstrip gas chamber hybrid detector

The gas proportional scintillation counter/microstrip gas chamber (GPSC/MSGC) hybrid detector for X-ray spectrometry is described. The detector uses a CsI-coated microstrip plate placed in direct contact with the gas-filling as the photosensor readout for the GPSC scintillation substituting for the photomultiplier tube (PMT). Usable photosensor maximum gain is limited by optical positive feedba...

متن کامل

Counting Aqueous Samples with the TopCount Microplate Scintillation Counter

The TopCountTM Microplate Scintillation Counter quantitates radioisotopes by liquid scintillation counting in standard microplate formats. Assays that previously had to be transferred from microplates to vials or to non-standard formats for counting can now be quantitated directly in microplates. TopCount can count up to 12 samples simultaneously with performance comparable to that of discrete ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Review of Scientific Instruments

سال: 1962

ISSN: 0034-6748,1089-7623

DOI: 10.1063/1.1717948