Tray Columns: Design

Distillation has remained an important separation technology for the chemical process industries. In 1997 it was reported in the journal Chemical Engineering that about 95% of all worldwide separation processes use this technology. In the USA alone, some 40000 distillation columns represent a capital investment of about US $8 billion. They consume the energy equivalent of approximately 1 billio...

متن کامل

A new approach to the design of internally heat-integrated tray distillation columns

Internally heat integrated distillation column has received a great attention lately because of its ultimate potential for energy savings. Typical conceptual design of such columns is based on constant heat transfer duties along the column stages. This paper introduces more effective approach to conceptual design of heat integrated distillation columns based on constant available heat transfer ...

متن کامل

Hydrodynamics of Sieve Tray Distillation Column Using CFD Simulation

Sieve trays are widely used in the gas- liquid contactors such as distillation and absorption towers. In this article, a three-dimensional, two phase CFD model using Euler-Euler framework was developed to simulate a distillation tower with two sieve trays. Hydrodynamic simulation of air and water system in different rates of gas phase was carried out and velocity distribution parameters, clear ...

متن کامل

CFD Simulation of Concap Tray Hydrodynamics

This research includes both experimental and CFD investigation in the hydrodynamic behavior of a new type of column tray introduced as “Concap” tray. The proposed column tray is used in contactor columns especially in stripping columns. The hydrodynamics of this Concap tray is investigated in a 1.2m in diameter column. Using air-water system, the experiments were performed for different liquid ...

متن کامل

A circumferentially flanged tibial tray minimizes bone-tray shear micromotion.

Aseptic loosening of the tibial component is the major complication of total knee arthroplasty. There is an association between early excessive shear micromotion between the bone and the tray of the tibial component and late aseptic loosening. Using non-linear finite element analysis, whether a tibial tray with a circumferentially flanged rim and a mating cut in the proximal tibia could minimiz...

متن کامل