Total reflection X-ray fluorescence spectrometry for trace determination of iron and some additional elements in biological samples
نویسندگان
چکیده
منابع مشابه
application and construction of carbon paste modified electrodes developed for determination of metal ions in some real samples
ساخت الکترودهاِی اصلاح شده ِیکِی از چالشهاِی همِیشگِی در دانش شیمِی بوِیژه شیمِی تجزیه مِی باشد ،که با در نظر گرفتن سادگِی ساخت، کاربردی بودن و ارزان بودن روش مِی توان به باارزش بودن چنِین سنسورهاِی پِی برد.آنچه که در ادامه آورده شده به ساخت و کاربرد الکترودهاِی اصلاح شده با استفاده از نانو ذرات در اندازه گِیرِی ولتامترِی آهن وکادمِیم اشاره دارد. کار اول اختصاص دارد به ساخت الکترود خمِیر کربن اصلاح شده با لِیگاند داِ...
15 صفحه اولAnalytical possibilities of total reflection X-ray spectrometry (TXRF) for trace selenium determination in soils.
Selenium content of soils is an important issue due to the narrow range between the nutritious requirement and toxic effects upon Se exposure. However, its determination is challenging due to low concentrations within complex matrices that hamper the analysis in most spectroscopic techniques. In this study, we explored the possibilities of several analytical approaches combined with total refle...
متن کاملAnalytical approaches for Hg determination in wastewater samples by means of total reflection X-ray fluorescence spectrometry.
At present, there is a considerable interest in Hg monitoring in wastewater samples due to its widespread occurrence and the high toxicity of most of its compounds. Hg determination in water samples by means of total reflection X-ray fluorescence spectrometry (TXRF) entails some difficulties due to the high vapor pressure and low boiling point of this element that produce evaporation and loss o...
متن کاملDetermination of trace elements in blood serum of patients with Behçet disease by total reflection x-ray fluorescence analysis.
The distribution of trace elements Fe, Cu, Zn, Se, and Rb was determined in sera from patients with the complete type of Behçet disease in the active stage and from healthy controls. Total reflection x-ray fluorescence was used for quantitative analysis; in general, atomic absorption spectrometry was used only for control of the Se values. Zn, Se, and Rb concentrations were significantly (P < 0...
متن کاملSimultaneous determination of trace elements in serum by energy-dispersive x-ray fluorescence spectrometry.
Energy-dispersive x-ray fluorescence is applied in the analysis of human serum to determine the concentrations of several elements simultaneously with minimal manipulation of the sample. The analytical procedure has been developed with standard sera, and standardization, detection limits, and reproducibility have been established. A 50-microL sample of diluted serum, to which an internal standa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Analytical and Bioanalytical Chemistry
سال: 2020
ISSN: 1618-2642,1618-2650
DOI: 10.1007/s00216-020-02614-8