Toric phakic intraocular lens

نویسندگان

چکیده

This 30-year-old patient had a high myopia and with-the-rule astigmatism. Her best-corrected-visual-acuity was 20/20 with -6.75 -2.50 x 10. cornea an asymmetric bowtie, we were concerned laser vision correction. We then decided to implant toric phakic intraocular lens (Visian ICL® toric) and, 1 week after surgery, she J1 uncorrected. Note the central anterior vaulting of away from crystalline lens, as well hole allow for aqueous [...]

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Toric phakic intraocular lens: European multicenter study.

OBJECTIVE To evaluate safety, efficacy, predictability, stability, complications, and patient satisfaction after implantation of Artisan toric phakic intraocular lenses (TPIOLs) for the correction of myopia or hyperopia with astigmatism. DESIGN Prospective, nonrandomized, comparative (self-controlled) multicenter trial. PARTICIPANTS Seventy eyes of 53 patients (mean, 35 years; range, 22-59 ...

متن کامل

Artiflex Toric Phakic Intraocular Lens Implantation in Congenital Nystagmus

CASE A 44-year-old woman with congenital nystagmus and myopic astigmatism in both eyes who was submitted to phakic intraocular lens (pIOL) implantation. METHODS Full ophthalmologic examination including refractive status, corrected (CDVA) and uncorrected (UCVA) monocular and binocular visual acuities, ocular motility, slit-lamp evaluation, tonometry and fundoscopy before and after implantatio...

متن کامل

Iris-fixated toric phakic intraocular lens: Three-year follow-up.

PURPOSE To evaluate the 3-year safety, efficacy, predictability, and stability of iris-fixated toric phakic intraocular lens (pIOL) implantation for the correction of myopia or hyperopia with astigmatism. SETTING Department of Ophthalmology, Johannes Gutenberg University, Mainz, and Department of Ophthalmology, University Clinic, Bochum, Germany. METHODS A prospective clinical trial of 40 e...

متن کامل

Lens vacuoles during phakic intraocular lens implantation

Lens damage during phakic intraocular lens implantation is a major complication. A case of a patient who developed lens vacuoles during toric implantable collamer lens (ICL) removal from her right eye and insertion of a new non-toric ICL due to persistent rotation of the former is presented in this work. As this event is very uncommon when implanting phakic intraocular lenses, the performed sur...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Revista Brasileira De Oftalmologia

سال: 2023

ISSN: ['0034-7280', '1982-8551']

DOI: https://doi.org/10.37039/1982.8551.20230033