Topology Optimization of Patient-Specific Custom-Fit Distal Tibia Plate: A Spiral Distal Tibia Bone Fracture
نویسندگان
چکیده
Currently, bone fractures are commonly treated with fixation plates that present rigid designs and stiff biometals (e.g., Ti-6Al-4V) increase the probability of stress shielding happening during remodeling by required stimuli for adequate healing. This can lead to medical implant loosening, resorption possible refracture. In this paper, an initial custom-fit plate is designed be based on computer tomography imaging a patient suffering from distal tibia spiral fracture. The was redesigned reduce risk being shielded. Topology optimization were implemented redesign minimizing strain energy reducing total plate’s volume in three different cases (25%, 50% 75%). A bone-plate construct assembled examined using finite element analysis considering load conditions patient’s gait loaded 10% bodyweight. stresses evaluated order compare topology optimized design. findings show higher volume, transfer reduction increases fractured area reduces shielding. viable approach building
منابع مشابه
Minimally Invasive Plate Osteosynthesis with Locking Compression Plate for Distal Diametaphyseal Tibia Fracture
Distal diametaphyseal tibia fracture though requires operative treatment is difficult to manage. Conventional osteosynthesis is not suitable because distal tibia is subcutaneous bone with poor vascularity. Closed reduction and minimally invasive plate osteosynthesis (MIPO) with locking compression plate (LCP) has emerged as an alternative treatment option because it respects biology of distal t...
متن کاملMinimally invasive plate osteosynthesis with locking compression plate for distal diametaphyseal tibia fracture.
BACKGROUND Distal diametaphyseal tibia fracture though requires operative treatment is difficult to manage. Conventional osteosynthesis is not suitable because distal tibia is subcutaneous bone with poor vascularity. Closed reduction and minimally invasive plate osteosynthesis (MIPO) with locking compression plate (LCP) has emerged as an alternative treatment option because it respects biology ...
متن کاملPercutaneous plate fixation of fractures of the distal tibia.
Minimally invasive plate osteosynthesis (MIPO) of the distal tibia offers several theoretical advantages compared to classic open reduction and internal fixation. A mechanically stable fracture-bridging osteosynthesis can be obtained without significant dissection and surgical trauma to the bone and surrounding soft tissues. In this retrospective study we looked at the results and complications...
متن کاملMinimal invasive plate osteosynthesis of close fractures of distal tibia.
BACKGROUND The limited soft tissue, subcutaneous location and poor vascularity render the tibial fractures very challenging. Treatment of distal tibial fractures using minimally invasive plate osteosynthesis (MIPO) technique may minimise damage to soft tissues and the vascular integrity of bony fragments, leaving comminuted fragments out of the mechanical construct, preserving soft tissues with...
متن کاملMinimally invasive percutaneous plate fixation of distal tibia fractures.
We report a series of 42 patients reviewed at a mean of 19.6 months after treatment of distal tibial and pilon fractures using the AO distal tibia locking plate with a minimally invasive percutaneous plate osteosynthesis (MIPPO) technique. Mean time to union was 22.4 weeks. All fractures united with acceptable alignment and angulation. Two cases of superficial infection were noted, with one cas...