Tophus resolution with pegloticase: a prospective dual-energy CT study

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tophus resolution with pegloticase: a prospective dual-energy CT study

OBJECTIVE To investigate the effect of intensive lowering of serum uric acid (SUA) levels by pegloticase on the resolution of tophi in patients with refractory gout. METHODS Descriptive study in patients with refractory gout receiving pegloticase treatment. SUA levels were measured before and after each infusion. Dual-energy CT (DECT) scans were taken from all patients before the first infusi...

متن کامل

A novel dual energy CT-based attenuation correction method in PET/CT systems: A phantom study

  In present PET/CT scanners, PET attenuation correction is performed by relying on the information given by CT scan. In the CT-based attenuation correction methods, dual-energy technique (DECT) is the most accurate approach, which has been limited due to the increasing patient dose. In this feasibility study, we have introduced a new method that can implement dual-en...

متن کامل

a novel dual energy ct-based attenuation correction method in pet/ct systems: a phantom study

in present pet/ct scanners, pet attenuation correction is performed by relying on the information given by ct scan. in the ct-based attenuation correction methods, dual-energy technique (dect) is the most accurate approach, which has been limited due to the increasing patient dose. in this feasibility study, we have introduced a new method that can implement dual-energy technique with only a si...

متن کامل

Stomach Virtual Non-Enhanced CT with Second-Generation, Dual-Energy CT: A Preliminary Study

OBJECTIVES To compare the true non-enhanced (TNE) and virtual non-enhanced (VNE) data sets in patients who underwent gastric preoperative dual-energy CT (DECT) and to evaluate potential radiation dose reduction by omitting a TNE scan. METHODS A total of 74 patients underwent gastric DECT. The mean CT values, length, image quality and effective radiation doses for VNE and TNE images were compa...

متن کامل

Dual-Energy CT in Neuroimaging

Image contrast in CT is mostly dependent on elements with high atomic weight, such as calcium, iron, and iodine The concentrations of these elements can be calculated from dual-energy x-ray data based on their characteristic attenuation patterns Dual-energy CT may can be helpful in neuroimaging to: Differentiate between hemorrhage and iodinated contrast agents in brain parenchyma Improve CT ang...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: RMD Open

سال: 2015

ISSN: 2056-5933

DOI: 10.1136/rmdopen-2015-000075