Tonometry: a Tonometer with Convex Plunger.
Naumoff,--Ueber einige path. anat. Veranderungen im Augengrunde bei neugebor. Kindern. Arch. f. O>ht1lal., Bd. XXXVI. Parsons.-The pathology of the eye. Vol. III, pt. i, 1906 Schleich.-Mittheilungen aus der ophthal. Klinik in Tubingen. 1884. Silcock, A. Quarry.-Trans. Ophthal. Soc. U.K., Vol. XX, 1900. Strahl. -Zur Entwickel. des menschl. Auges. Anat. Anzeig. Bd. XIV, 1898. Stumpf and Sicherer....
متن کاملClinical comparison of the Icare tonometer and Goldmann applanation tonometry.
PURPOSE To compare a new method of intraocular pressure (IOP) measurement, using the Icare tonometer, with Goldmann applanation tonometry (GAT). PATIENTS AND METHODS Two observers obtained IOP readings in 292 eyes (143 right and 149 left) of 153 subjects, using the Icare without topical anesthetic. A GAT reading was subsequently obtained by a consultant ophthalmologist, without the knowledge ...
متن کاملA Comparison of the Icare Pro Rebound Tonometer with Applanation Tonometry in Healthy Infants
The measurement of intraocular pressure (IOP) in children is an important component of the ocular examination, but can be challenging, especially in younger children and infants. Clinical suspicion of raised IOP necessitates examination under anaesthesia. This is costly [1], associated with potentially serious adverse events [2], including developmental delay [3], and uses valuable paediatric t...
متن کاملComparison of three methods of tonometry in normal subjects: Goldmann applanation tonometer, non-contact airpuff tonometer, and Tono-Pen XL
OBJECTIVE WE AIMED TO COMPARE INTRAOCULAR PRESSURE (IOP) MEASUREMENTS VIA THREE DIFFERENT TONOMETERS: the Goldmann applanation tonometer (GAT), the Tono-Pen(®) XL (TPXL), and a non-contact airpuff tonometer (NCT). METHODS This was a cross-sectional study of 200 eyes from 200 patients. Right eyes of all patients were included in this study. IOP was measured via GAT, NCT, and TPXL by three phys...
متن کاملComparison of intraocular pressure measurements with the portable PT100 noncontact tonometer and goldmann applanation tonometry
PURPOSE Noncontact tonometers are useful when regulations preclude use of contact tonometers by medical students and other nonophthalmologists. Our study compared the measurements by the portable, noncontact tonometer (PT100) with Goldmann applanation tonometry (GAT). METHODS This was a prospective study of 98 eyes from 98 patients. Intraocular pressure (IOP) was measured by GAT and the PT100...