Titanium Alloy Stem as a Cause for Adverse Reaction to Metal Debris after Bipolar Hemiarthroplasty

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Titanium Alloy Stem as a Cause for Adverse Reaction to Metal Debris after Bipolar Hemiarthroplasty

A 68-year-old male with failure of bipolar hemiarthroplasty consistent with adverse reaction to metal debris (ARMD) who presented with a painful cystic lesion and lower extremity swelling was encountered. However, revision surgical findings showed no apparent cause of ARMD previously described in the literature, such as corrosion at the head-neck junction and articular abrasion. Therefore, it w...

متن کامل

Adverse reaction to metal debris in a painful hemiarthroplasty of the hip

Adverse reaction to metal debris (ARMD) in total hip arthroplasty surgery is a well-known problem. We present the case of a unipolar hemiarthroplasty requiring revision within 18 months of insertion secondary to an adverse reaction to metal debris. This case demonstrates a rare cause for failure of a hemiarthroplasty following a fragility fracture. We feel that ARMD should be considered in all ...

متن کامل

Adverse reaction to metal debris after Birmingham hip resurfacing arthroplasty

BACKGROUND AND PURPOSE Concern has emerged about local soft-tissue reactions after hip resurfacing arthroplasty (HRA). The Birmingham Hip Resurfacing (BHR) was the most commonly used HRA device at our institution. We assessed the prevalence and risk factors for adverse reaction to metal debris (ARMD) with this device. PATIENTS AND METHODS From 2003 to 2011, BHR was the most commonly used HRA ...

متن کامل

Adverse reaction to metal debris: metallosis of the resurfaced hip

The greatest concern after metal-on-metal hip resurfacing may be the development of metallosis. Metallosis is an adverse tissue reaction to the metal debris generated by the prosthesis and can be seen with implants and joint prostheses. The reasons patients develop metallosis are multifactorial, involving patient, surgical, and implant factors. Contributing factors may include component malposi...

متن کامل

Adverse reaction to metal debris after ReCap-M2A-Magnum large-diameter-head metal-on-metal total hip arthroplasty

BACKGROUND AND PURPOSE The clinical findings of adverse reaction to metal debris (ARMD) following large-diameter-head metal-on-metal total hip arthroplasty (LDH MoM THA) may include periarticular fluid collections, soft tissue masses, and gluteal muscle necrosis. The ReCap-M2a-Magnum LDH MoM THA was the most commonly used hip device at our institution from 2005 to 2012. We assessed the prevalen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Case Reports in Orthopedics

سال: 2014

ISSN: 2090-6749,2090-6757

DOI: 10.1155/2014/209461