Time-series absolute radiometric calibration and trend analysis of the wide swath sensor onboard GF-6 satellite with automatic radiometric calibration site
نویسندگان
چکیده
å«æé¥æè½½è·å¨è½¨ç»å¯¹è¾å°å®æ 对ä¿è¯ä¸åæ¥æºäº§åçè¾å°ä¸è´æ§åæåé«åå ±æ§äº§ååæ¼ç²¾åº¦è³å ³éè¦ãä¼ ç»åºäºäººå·¥åæ¥æµéçåºå°å®æ æ¹æ³ç±äºåå°å«æè¿å¢æ¶å»æåæ¡ä»¶ãå°è¡¨åå¤§æ°æµéæ¡ä»¶çéå¶ï¼é¾ä»¥æ»¡è¶³åç¡®æ ¡æ£é¥æè½½è·èªèº«è¾å°æ§è½å¨çå½å¨æå ååçéæ±ãæ¬æé对å½äº§é«åå å·å®½å¹ è½½è·ï¼GF-6/WFVï¼å¤§è§åº¦è§æµçç¹ç¹ï¼æåºäºå©ç¨èªå¨è¾å°å®æ åºçGF-6/WFVè½½è·å¨è½¨æ¶åºç»å¯¹è¾å°å®æ æ¹æ³ï¼åºäºè¯¥æ¹æ³å¯å¾å°è½½è·å¯éåçæ¶åºç»å¯¹è¾å°å®æ ç»æåå ¶ä¸ç¡®å®åº¦ï¼å¹¶ä¸éè¿æ¾èæåå¨è½¨å®æ 颿¬¡å®ç°å«æè½½è·è¾å°æ§è½çè¶å¿ååæç»è·è¸ªãåºäºè¯¥æ¹æ³å®ç°äº2019å¹´8æè³2021å¹´10ææé´è¿å¢èªå¨è¾å°å®æ åº41颿¬¡çGF-6/WFVèªå¨è¾å°å®æ ä¸å®æ ç»æçä¸ç¡®å®åº¦ä¼äº5%ï¼ç¬¬7波段é¤å¤ï¼ï¼å¯¹æ¶åºå®æ ç»æè¿è¡è¶å¿åæå¾å°GF-6/WFVè½½è·å波段è¾å°å®æ ç³»æ°å¹´ååå¨1.10%â4.59%ï¼æ¤å¤ï¼ä»¥é«ç²¾åº¦å¨è½¨å«æè½½è·MODISåSentinel-2/MSI为åèçGF-6/WFVè½½è·ç¬¬1è³ç¬¬4波段交åéªè¯ç»æçç¸å¯¹å·®å¼ç»å¯¹å¹³åå¼å¨2.12%â6.09%ãè¯´ææ¬ææ¹æ³å¯å®ç°GF-6/WFVè½½è·çæ¶åºå¨è½¨ç»å¯¹è¾å°å®æ åå ¨çå½å¨æè¾å°æ§è½çè¶å¿ååçæµï¼æææ¯æå½äº§é«åå ±æ§é¥æäº§åç产åæåå½äº§é¥ææ°æ®å®éååºç¨æ°´å¹³ã
منابع مشابه
Tuz Gölü: New Absolute Radiometric Calibration Test Site
Calibration, absolute radiometric calibration in specific, is an important process for continuity and reliability of optical satellite data, since it puts the data on a standard scale and makes it compatible and comparable with the data acquired from different sensors. Therefore, the importance of performing a calibration campaign increased significantly. Being aware of this significance, TUBIT...
متن کاملRadiometric Self Calibration
A simple algorithm is described that computes the radiometric response function of an imaging system, from images of an arbitrar), scene taken using different exposures. The exposure is varied by changing either the aperture setting or the shutter speed. The algorithm does not require precise estimates of the exposures used. Rough estimates of the ratios of the exposures (e.g. Fnumber settings ...
متن کاملAbsolute Radiometric Calibration of the Novel DLR “Kalibri” Transponder
The technological advancement of the synthetic aperture radar (SAR) principle leads to an innovative challenge for the calibration as well. In order to provide an active reference target for an accurate absolute radiometric calibration the knowledge of the target’s backscattering characteristics is essential. For the recently developed DLR C-band transponder named “Kalibri” several strategies f...
متن کاملRadiometric Cross-Calibration of GF-4 in Multispectral Bands
The GaoFen-4 (GF-4), launched at the end of December 2015, is China’s first high-resolution geostationary optical satellite. A panchromatic and multispectral sensor (PMS) is onboard the GF-4 satellite. Unfortunately, the GF-4 has no onboard calibration assembly, so on-orbit radiometric calibration is required. Like the charge-coupled device (CCD) onboard HuanJing-1 (HJ) or the wide field of vie...
متن کاملThe Ground-Based Absolute Radiometric Calibration of Landsat 8 OLI
This paper presents the vicarious calibration results of Landsat 8 OLI that were obtained using the reflectance-based approach at test sites in Nevada, California, Arizona, and South Dakota, USA. Additional data were obtained using the Radiometric Calibration Test Site, which is a suite of instruments located at Railroad Valley, Nevada, USA. The results for the top-of-atmosphere spectral radian...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of remote sensing
سال: 2023
ISSN: ['1007-4619', '2095-9494']
DOI: https://doi.org/10.11834/jrs.20232197