Time Response Analysis of Caissons by Installing New Caisson on Existing Caisson Breakwater in Irregular Wave Condition

نویسندگان

چکیده

The design and the construction were carried out by installing new caissons on back or front of existing to increase structural stability caisson breakwaters. In this study, we used ANSYS AQWA program analyze wave forces acting individual according effects wave-structure interaction when additionally installed force characteristics analyzed distance among in frequency domain analysis. addition, dynamic closely examined basis at which unusual distribution occurs irregular conditions using time

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A numerical simulation on seepage-induced collapse of caisson breakwater using a stabilized ISPH method

The clarification on the collapse mechanism of a caisson breakwater has been an urgent task in order to reduce damages caused by next millennium tsunamis. In this study, piping destruction of a mound induced by seepage flow is taken into consideration solely. A stabilized ISPH method proposed by Asai (2012) is adopted with some modification associated with the extended Darcy law (Akbari 2013, 2...

متن کامل

The Expected Sliding Distance Model of Meandering Damage for Caisson Breakwater

In the past decades, many references have studied the mechanics of meandering damage for breakwater. However, up to the present time, no model has been proposed to compute the consequence of this kind of damage quantitatively. So, this paper tries to solve this problem by combining the expected sliding distance technique and the diffraction model. 1 Preface The meandering damage of breakwater i...

متن کامل

Decompression sickness in caisson workers.

El Ghawabi, S. H., Mansour, M. B., Youssef, F. L., El Ghawabi, M. H., and Abd El Latif, M. M. (1971). Brit. J. industr. Med., 28, 323-329. Decompression sickness in caisson workers. An investigation of 55 bridge construction workers is reported. The overall bends rate was 097 %. (The term 'bends' as used in this study is defined in the paper.) Chokes were encountered in 67-27% of workers. A cli...

متن کامل

Design, Analysis and Verification of Moored Floating Caisson System

Tacoma Narrows Constructors (TNC) is building a new suspension bridge in Tacoma, close to Seattle, Washington State, USA. The new bridge will be built just south of the existing bridge mounted on two caissons, referred to as East Caisson (Tacoma side) and West Caisson (Gig Harbor side). Each pier is about 80’ wide and 130’ long in plan. The mooring system for each caisson consists of two sets o...

متن کامل

Evaluation of Vibration Characteristics of Caisson-Type Breakwater Using Impact Vibration Tests and Validation of Numerical Analysis Model

In this study, ambient and forced vibration tests are proposed to evaluate dynamic characteristics of a caisson-type breakwater including natural frequencies and modal damping ratios, and the feasibility of numerical analysis model with fluid-structure-soil interaction effects, which plays an important role to evaluate structural performance and safety, is investigated by comparing the numerica...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Han-gug hae-an hae-yang gonghaghoe nonmunjib

سال: 2022

ISSN: ['1976-8192', '2288-2227']