Time-resolved Chemiluminescence Measurements for Photoinitiated Chemiluminescence Reactions.
نویسندگان
چکیده
منابع مشابه
Chemiluminescence and Bioluminescence Measurements .PDF
Chemiand bioluminescence measurements have become extremely popular in recent years. They are often used to determine the amount of a specific unknown present in a sample, and in the last decade, have become extremely important in the study of gene expression and gene regulation. Chemiluminescence is the light emitted by a chemical reaction and bioluminescence is a type of chemiluminescence in ...
متن کاملOrgan chemiluminescence: noninvasive assay for oxidative radical reactions.
In situ and perfused rat livers showed a spontaneous chemiluminescence of 7-12 counts/sec . cm2 (corresponding to 7-12 x 10(3) photons/sec . cm2); chemiluminescence was increased up to 30 times by infusion of exogenous hydroperoxides. The chemiluminescence of the perfused liver was oxygen dependent. Ethyl, t-butyl, and cumene hydroperoxides were almost equally effective in inducing light emissi...
متن کاملTime-resolved chemiluminescence technique for the microdetermination of proteins based on their complexation with copper(II).
Based on the complexation between proteins and Cu(II) coupled with the time-resolved chemiluminescence (CL) technique, a highly sensitive and quantitative assay for measuring proteins in solution is described. The complexes of proteins with Cu(II) have a strongly catalytic effect on the luminol-H2O2 CL reaction. Because the CL emission produced by the complexes is much more long-lived than that...
متن کاملMetal-enhanced chemiluminescence: advanced chemiluminescence concepts for the 21st century.
Chemiluminescent-based detection is entrenched throughout the biosciences today, such as in blotting, analyte and protein quantification and detection. While the biological applications of chemiluminescence are forever growing, the underlying principles of using a probe, an oxidizer and a catalyst (biological, organic or inorganic) have remained mostly unchanged for decades. Subsequently, chemi...
متن کاملChemiluminescence immunoassay
The use of chemiluininescent molecules as non—isotopic alternatives to 125 in immunoassay permits the development of sensitive, stable assay systems.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: NIPPON KAGAKU KAISHI
سال: 1997
ISSN: 2185-0925,0369-4577
DOI: 10.1246/nikkashi.1997.899